Worldwide wastewater treatment observatory · Belgium

Aguas SB Observatory · public data to understand water

WWTP MORNIMONT

Belgium · official identifier BERW9214001

45,000h-e design capacity (2022) · 46th of 397 (tied with 5 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier BERW9214001 · reported size 45,000 h-e design capacity · received load 44,467 h-e · reported treatment: PS · data year 2022. 46th of 397 records with reported size in the inventory of Belgium (tied with 5 others); 0.42 % of the sum of those 397 records in h-e (sum of records, not national capacity); nearest inventoried plant at 1.7 km · 14 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

45,000h-e design capacity
44,467h-e received load (2022)
99 %reported load/capacity ratio (not hydraulic utilisation)
46th of 397by reported size among the 397 records with a size in the inventory (tied with 5 others) · 0.42 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates50.4489, 4.7034 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Belgium

Regulatory framework of Belgium · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

2,203,206reference kWh per year for this load
49.6kWh per h-e (average load) per year
330,481€ per year at 0.15 €/kWh
46 %share of energy used for aeration

what this estimate is · Inputs: 44,467 p.e. of reported load; equivalent average load 44,433 p.e. with the reference profile of Belgium (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

5.8estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (15,964 m³/day of reference), not measured or available for reclamation.

LOCATION

Belgium: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Fosses-la-Ville · Berw92048025.3 km4,200875primary and secondary
Floreffe5.7 km23,0003,612primary and secondary
Saint-Martin7.4 km10,0003,363primary and secondary
Wanfercee-Baulet8.4 km10,8005,516primary and secondary
Bambois8.5 km1,260685primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP MORNIMONT report?

Reported size: 45,000 h-e design capacity. Received load: 44,467 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of MORNIMONT?

Aguas SB simulator reference scenario for 44,467 p.e. of reported load: 2,203,206 kWh per year (49.6 kWh per p.e. of average load), with aeration as 46 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.