Worldwide wastewater treatment observatory · Czechia

Aguas SB Observatory · public data to understand water

WWTP COV Dobrovice

Czechia · official identifier CZ2115-627470-46356983-4/1U

3,750h-e design capacity (2022) · 430th of 607 (tied with 2 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier CZ2115-627470-46356983-4/1U · reported size 3,750 h-e design capacity · received load 1,479 h-e · reported treatment: PS · data year 2022. 430th of 607 records with reported size in the inventory of Czechia (tied with 2 others); 0.03 % of the sum of those 607 records in h-e (sum of records, not national capacity); nearest inventoried plant at 8.7 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

3,750h-e design capacity
1,479h-e received load (2022)
39 %reported load/capacity ratio (not hydraulic utilisation)
430th of 607by reported size among the 607 records with a size in the inventory (tied with 2 others) · 0.03 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalyes
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates50.3584, 14.9632 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Czechia

Regulatory framework of Czechia · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

80,094reference kWh per year for this load
54.0kWh per h-e (average load) per year
12,014€ per year at 0.15 €/kWh
66 %share of energy used for aeration

what this estimate is · Inputs: 1,479 p.e. of reported load; equivalent average load 1,484 p.e. with the reference profile of Czechia (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (352 m³/day of reference), not measured or available for reclamation.

LOCATION

Czechia: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Cov Mlada Boleslav - Neuberk8.7 km40,00042,744primary and secondary
Cov Mlada Boleslav - Podlazky8.8 km68,00039,991primary and secondary
Cov Benatky Nad Jizerou13.2 km9,9007,127primary and secondary
Cov Bakov Nad Jizerou13.2 km5,0003,056primary and secondary
Cov Dolni Bousov14.4 km2,5002,475primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP COV Dobrovice report?

Reported size: 3,750 h-e design capacity. Received load: 1,479 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of COV Dobrovice?

Aguas SB simulator reference scenario for 1,479 p.e. of reported load: 80,094 kWh per year (54.0 kWh per p.e. of average load), with aeration as 66 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.