Worldwide wastewater treatment observatory · Czechia

Aguas SB Observatory · public data to understand water

WWTP COV Jihlava · CZ6105-648698-00286010-4/1U

Czechia · official identifier CZ6105-648698-00286010-4/1U

99,917h-e design capacity (2022) · 25th of 607

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier CZ6105-648698-00286010-4/1U · reported size 99,917 h-e design capacity · received load 75,059 h-e · reported treatment: PS · data year 2022. 25th of 607 records with reported size in the inventory of Czechia; 0.67 % of the sum of those 607 records in h-e (sum of records, not national capacity). Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

Aerial image withheld. The reported coordinate matches another facility or is missing: the location awaits cross-checking. The table retains the reported data.

WHAT THE DATA REPORT

Reported data official data · 2022

99,917h-e design capacity
75,059h-e received load (2022)
75 %reported load/capacity ratio (not hydraulic utilisation)
25th of 607by reported size among the 607 records with a size in the inventory · 0.67 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates49.4050, 15.6094 approximate position · location awaiting cross-checking
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Czechia

Regulatory framework of Czechia · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

2,964,828reference kWh per year for this load
39.4kWh per h-e (average load) per year
444,724€ per year at 0.15 €/kWh
54 %share of energy used for aeration

what this estimate is · Inputs: 75,059 p.e. of reported load; equivalent average load 75,327 p.e. with the reference profile of Czechia (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

6.5estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (17,864 m³/day of reference), not measured or available for reclamation.

LOCATION

Czechia: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

Nearby plants are not shown: this plant's location awaits cross-checking.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP COV Jihlava · CZ6105-648698-00286010-4/1U report?

Reported size: 99,917 h-e design capacity. Received load: 75,059 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of COV Jihlava · CZ6105-648698-00286010-4/1U?

Aguas SB simulator reference scenario for 75,059 p.e. of reported load: 2,964,828 kWh per year (39.4 kWh per p.e. of average load), with aeration as 54 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.