Worldwide wastewater treatment observatory · Czechia

Aguas SB Observatory · public data to understand water

WWTP COV Pec pod Snezkou

Czechia · official identifier CZ5214-718637-60108711-4/1U

8,050h-e design capacity (2022) · 233rd of 607

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier CZ5214-718637-60108711-4/1U · reported size 8,050 h-e design capacity · received load 3,872 h-e · reported treatment: PS · data year 2022. 233rd of 607 records with reported size in the inventory of Czechia; 0.05 % of the sum of those 607 records in h-e (sum of records, not national capacity); nearest inventoried plant at 10.8 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

8,050h-e design capacity
3,872h-e received load (2022)
48 %reported load/capacity ratio (not hydraulic utilisation)
233rd of 607by reported size among the 607 records with a size in the inventory · 0.05 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates50.6959, 15.7397 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Czechia

Regulatory framework of Czechia · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

195,616reference kWh per year for this load
50.3kWh per h-e (average load) per year
29,342€ per year at 0.15 €/kWh
70 %share of energy used for aeration

what this estimate is · Inputs: 3,872 p.e. of reported load; equivalent average load 3,888 p.e. with the reference profile of Czechia (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.3estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (922 m³/day of reference), not measured or available for reclamation.

LOCATION

Czechia: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Cov Spindleruv Mlyn10.8 km12,0008,109primary and secondary
Cov Bobr12.2 km3,5361,492primary, secondary and tertiary
Cov Vrchlabi - Podhuri14.5 km18,50014,648primary and secondary
Cov Jilemnice - Devro18.8 km28,85218,998primary, secondary and tertiary
Cov Hostinne - Dlouha Louka19.3 km7,2304,414primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP COV Pec pod Snezkou report?

Reported size: 8,050 h-e design capacity. Received load: 3,872 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of COV Pec pod Snezkou?

Aguas SB simulator reference scenario for 3,872 p.e. of reported load: 195,616 kWh per year (50.3 kWh per p.e. of average load), with aeration as 70 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.