WWTP COV Prelouc
Czechia · official identifier CZ5311-734560-60108631-4/1U
10,500h-e design capacity (2022) · 190th of 607
European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier CZ5311-734560-60108631-4/1U · reported size 10,500 h-e design capacity · received load 6,442 h-e · reported treatment: PS · data year 2022. 190th of 607 records with reported size in the inventory of Czechia; 0.07 % of the sum of those 607 records in h-e (sum of records, not national capacity); nearest inventoried plant at 10.1 km. Reported data with their source; estimates are not measurements of the plant.
Aguas SB does not manage this wastewater treatment plant.
WHAT THE DATA REPORT
Reported data official data · 2022
| Treatment | primary + secondary (as reported to the EEA: PS) · reported levels |
|---|---|
| Nitrogen removal | yes |
| Phosphorus removal | yes |
| UV disinfection | not reported |
| Status | active |
| Reported coordinates | 50.0439, 15.5544 precision reported by the source: level 2 what it means |
| Source and year | European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record |
REGULATORY REFERENCES
Referencia normativa: Czechia
Regulatory framework of Czechia · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.
SCENARIO
Reference energy scenario for this load estimate · simulator engine
what this estimate is · Inputs: 6,442 p.e. of reported load; equivalent average load 6,464 p.e. with the reference profile of Czechia (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.
Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.
WATER THAT COULD RETURN
Reuse potential
what this estimate is · Volume estimated from the reported load (1,533 m³/day of reference), not measured or available for reclamation.
NEARBY PLANTS
Nearby wastewater treatment plants
| Plant | Distance | Capacity (h-e) | Load 2022 | Treatment |
|---|---|---|---|---|
| Cov Pardubice - Rybitvi - Synthesia | 10.1 km | 297,000 | 96,073 | primary, secondary and tertiary |
| Cov Chvaletice | 10.4 km | 4,166 | 1,222 | primary and secondary |
| Cov Hermanuv Mestec | 13.0 km | 5,000 | 3,239 | primary and secondary |
| Cov Chlumec Nad Cidlinou | 13.2 km | 5,496 | 3,912 | primary and secondary |
| Cov Vrdy | 14.5 km | 3,000 | 2,131 | primary and secondary |
Distances are between reported coordinates; proximity does not establish a hydraulic connection.
QUESTIONS
Frequently asked questions about this plant
What capacity does WWTP COV Prelouc report?
Reported size: 10,500 h-e design capacity. Received load: 6,442 h-e. Units are retained without conversion.
What treatment is reported?
Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.
How much energy would a reference plant use with the load of COV Prelouc?
Aguas SB simulator reference scenario for 6,442 p.e. of reported load: 321,118 kWh per year (49.7 kWh per p.e. of average load), with aeration as 46 % of consumption. Estimate with the country reference profile; not a measurement of the plant.
SOURCE AND CORRECTIONS
Source
reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.