Worldwide wastewater treatment observatory · Denmark

Aguas SB Observatory · public data to understand water

WWTP Attrup

Denmark · official identifier DK8030009

22,000h-e design capacity (2022) · 113th of 321 (tied with 2 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier DK8030009 · reported size 22,000 h-e design capacity · received load 21,782 h-e · reported treatment: PST · data year 2022. 113th of 321 records with reported size in the inventory of Denmark (tied with 2 others); 0.18 % of the sum of those 321 records in h-e (sum of records, not national capacity); nearest inventoried plant at 12.4 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

22,000h-e design capacity
21,782h-e received load (2022)
99 %reported load/capacity ratio (not hydraulic utilisation)
113th of 321by reported size among the 321 records with a size in the inventory (tied with 2 others) · 0.18 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates57.0579, 9.4805 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Denmark

Regulatory framework of Denmark · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,121,428reference kWh per year for this load
52.7kWh per h-e (average load) per year
168,214€ per year at 0.15 €/kWh
47 %share of energy used for aeration

what this estimate is · Inputs: 21,782 p.e. of reported load; equivalent average load 21,294 p.e. with the reference profile of Denmark (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

2.5estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (6,796 m³/day of reference), not measured or available for reclamation.

LOCATION

Denmark: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Fjerritslev12.4 km10,6775,370primary, secondary and tertiary
Løgstør16.1 km70,00031,723primary, secondary and tertiary
Sigsgård20.5 km39,90020,196primary, secondary and tertiary
Aalborg Vest23.3 km227,000197,995primary, secondary and tertiary
Aars Renseanlæg27.7 km105,00035,332primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Attrup report?

Reported size: 22,000 h-e design capacity. Received load: 21,782 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Attrup?

Aguas SB simulator reference scenario for 21,782 p.e. of reported load: 1,121,428 kWh per year (52.7 kWh per p.e. of average load), with aeration as 47 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.