Worldwide wastewater treatment observatory · Denmark

Aguas SB Observatory · public data to understand water

WWTP Viborg Centralrenseanlæg

Denmark · official identifier DK7910202

80,000h-e design capacity (2022) · 39th of 321 (tied with 1 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier DK7910202 · reported size 80,000 h-e design capacity · received load 48,050 h-e · reported treatment: PST · data year 2022. 39th of 321 records with reported size in the inventory of Denmark (tied with 1 others); 0.65 % of the sum of those 321 records in h-e (sum of records, not national capacity); nearest inventoried plant at 13.4 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

80,000h-e design capacity
48,050h-e received load (2022)
60 %reported load/capacity ratio (not hydraulic utilisation)
39th of 321by reported size among the 321 records with a size in the inventory (tied with 1 others) · 0.65 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates56.4250, 9.4546 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Denmark

Regulatory framework of Denmark · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

2,234,391reference kWh per year for this load
47.6kWh per h-e (average load) per year
335,159€ per year at 0.15 €/kWh
49 %share of energy used for aeration

what this estimate is · Inputs: 48,050 p.e. of reported load; equivalent average load 46,975 p.e. with the reference profile of Denmark (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

5.5estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (14,992 m³/day of reference), not measured or available for reclamation.

LOCATION

Denmark: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Fiskbæk13.4 km4,4001,615primary, secondary and tertiary
Kjellerup14.9 km18,0006,566primary, secondary and tertiary
Bjerringbro15.0 km80,00013,745primary, secondary and tertiary
Skals15.7 km3,5001,716primary, secondary and tertiary
Bjerregrav16.6 km6,0505,013primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Viborg Centralrenseanlæg report?

Reported size: 80,000 h-e design capacity. Received load: 48,050 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Viborg Centralrenseanlæg?

Aguas SB simulator reference scenario for 48,050 p.e. of reported load: 2,234,391 kWh per year (47.6 kWh per p.e. of average load), with aeration as 49 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.