Worldwide wastewater treatment observatory · Finland

Aguas SB Observatory · public data to understand water

WWTP TP (258301) of Tornion kt.

Finland · official identifier FI_SE2583_01

60,000h-e design capacity (2022) · 31st of 145 (tied with 1 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier FI_SE2583_01 · reported size 60,000 h-e design capacity · received load 46,500 h-e · reported treatment: PST · data year 2022. 31st of 145 records with reported size in the inventory of Finland (tied with 1 others); 0.83 % of the sum of those 145 records in h-e (sum of records, not national capacity); nearest inventoried plant at 17.2 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

60,000h-e design capacity
46,500h-e received load (2022)
78 %reported load/capacity ratio (not hydraulic utilisation)
31st of 145by reported size among the 145 records with a size in the inventory (tied with 1 others) · 0.83 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalnot reported
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates65.8200, 24.1500 precision reported by the source: level 0 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Finland

Regulatory framework of Finland · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,783,420reference kWh per year for this load
38.3kWh per h-e (average load) per year
267,513€ per year at 0.15 €/kWh
58 %share of energy used for aeration

what this estimate is · Inputs: 46,500 p.e. of reported load; equivalent average load 46,522 p.e. with the reference profile of Finland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

3estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (8,138 m³/day of reference), not measured or available for reclamation.

LOCATION

Finland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Tp (249) Of Kemin Kt.17.2 km16,5007,200primary, secondary and tertiary
Tp (246) Of Kemin Kt.22.5 km35,00016,700primary, secondary and tertiary
Tp (714) Of Rovaniemen Kt.99.7 km55,00055,000primary, secondary and tertiary
Tp (578) Of Oulu103.6 km214,500211,000primary, secondary and tertiary
Tp (251) Of Kempele119.3 km60,00031,200primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP TP (258301) of Tornion kt. report?

Reported size: 60,000 h-e design capacity. Received load: 46,500 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of TP (258301) of Tornion kt.?

Aguas SB simulator reference scenario for 46,500 p.e. of reported load: 1,783,420 kWh per year (38.3 kWh per p.e. of average load), with aeration as 58 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.