Worldwide wastewater treatment observatory · France

Aguas SB Observatory · public data to understand water

WWTP AIRVAULT LE PRE NEUF

France · official identifier FR0479005S0004

4,600h-e design capacity (2022) · 2414th of 4,051 (tied with 8 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier FR0479005S0004 · reported size 4,600 h-e design capacity · received load 1,560 h-e · reported treatment: PST · data year 2022. 2414th of 4,051 records with reported size in the inventory of France (tied with 8 others); < 0.01 % of the sum of those 4,051 records in h-e (sum of records, not national capacity); nearest inventoried plant at 9.5 km · 1 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

4,600h-e design capacity
1,560h-e received load (2022)
34 %reported load/capacity ratio (not hydraulic utilisation)
2414th of 4,051by reported size among the 4,051 records with a size in the inventory (tied with 8 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates46.8233, -0.1459 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: France

Regulatory framework of France · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

74,385reference kWh per year for this load
47.7kWh per h-e (average load) per year
11,158€ per year at 0.15 €/kWh
70 %share of energy used for aeration

what this estimate is · Inputs: 1,560 p.e. of reported load; equivalent average load 1,559 p.e. with the reference profile of France (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (226 m³/day of reference), not measured or available for reclamation.

LOCATION

France: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Saint-Varent Le Ruisseau9.5 km2,5001,382primary, secondary and tertiary
Parthenay Pompairain19.9 km42,50026,804primary, secondary and tertiary
Thouars Sainte-Verge21.2 km35,00026,279primary, secondary and tertiary
Mirebeau24.2 km15,00011,456primary, secondary and tertiary
Bressuire Rheas27.0 km60,00036,506primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP AIRVAULT LE PRE NEUF report?

Reported size: 4,600 h-e design capacity. Received load: 1,560 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of AIRVAULT LE PRE NEUF?

Aguas SB simulator reference scenario for 1,560 p.e. of reported load: 74,385 kWh per year (47.7 kWh per p.e. of average load), with aeration as 70 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.