Worldwide wastewater treatment observatory · France

Aguas SB Observatory · public data to understand water

WWTP CADENET

France · official identifier FR060984026003

4,600h-e design capacity (2022) · 2414th of 4,051 (tied with 8 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier FR060984026003 · reported size 4,600 h-e design capacity · received load 2,605 h-e · reported treatment: PS · data year 2022. 2414th of 4,051 records with reported size in the inventory of France (tied with 8 others); < 0.01 % of the sum of those 4,051 records in h-e (sum of records, not national capacity); nearest inventoried plant at 3.5 km · 6 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

4,600h-e design capacity
2,605h-e received load (2022)
57 %reported load/capacity ratio (not hydraulic utilisation)
2414th of 4,051by reported size among the 4,051 records with a size in the inventory (tied with 8 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates43.7186, 5.3503 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: France

Regulatory framework of France · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

120,206reference kWh per year for this load
46.1kWh per h-e (average load) per year
18,031€ per year at 0.15 €/kWh
73 %share of energy used for aeration

what this estimate is · Inputs: 2,605 p.e. of reported load; equivalent average load 2,608 p.e. with the reference profile of France (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (378 m³/day of reference), not measured or available for reclamation.

LOCATION

France: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
La Roque D'Antheron Nouvelle3.5 km12,0007,280primary and secondary
Lauris4.8 km4,5003,057primary and secondary
Villelaure5.9 km2,7002,633primary, secondary and tertiary
Charleval8.8 km3,0003,391primary and secondary
Puy Ste Reparade8.9 km5,6003,408primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP CADENET report?

Reported size: 4,600 h-e design capacity. Received load: 2,605 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of CADENET?

Aguas SB simulator reference scenario for 2,605 p.e. of reported load: 120,206 kWh per year (46.1 kWh per p.e. of average load), with aeration as 73 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.