Worldwide wastewater treatment observatory · France

Aguas SB Observatory · public data to understand water

WWTP COUARDE SUR MER

France · official identifier FR0417121S0001

37,333h-e design capacity (2022) · 455th of 4,051

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier FR0417121S0001 · reported size 37,333 h-e design capacity · received load 25,354 h-e · reported treatment: PST · data year 2022. 455th of 4,051 records with reported size in the inventory of France; 0.04 % of the sum of those 4,051 records in h-e (sum of records, not national capacity); nearest inventoried plant at 7.5 km · 4 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

37,333h-e design capacity
25,354h-e received load (2022)
68 %reported load/capacity ratio (not hydraulic utilisation)
455th of 4,051by reported size among the 4,051 records with a size in the inventory · 0.04 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionyes
Statusactive
Reported coordinates46.2022, -1.4297 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: France

Regulatory framework of France · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,012,666reference kWh per year for this load
39.9kWh per h-e (average load) per year
151,900€ per year at 0.15 €/kWh
59 %share of energy used for aeration

what this estimate is · Inputs: 25,354 p.e. of reported load; equivalent average load 25,364 p.e. with the reference profile of France (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

1.3estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (3,676 m³/day of reference), not measured or available for reclamation.

LOCATION

France: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Flotte (La) Clos Martin7.5 km36,00024,780primary, secondary and tertiary
Portes en Re7.7 km8,0004,184primary, secondary and tertiary
Ars-en-Re8.2 km23,00017,117primary, secondary and tertiary
Sainte Marie de Re9.4 km30,00018,213primary, secondary and tertiary
Tranche-Sur-Mer17.4 km32,00024,928primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP COUARDE SUR MER report?

Reported size: 37,333 h-e design capacity. Received load: 25,354 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of COUARDE SUR MER?

Aguas SB simulator reference scenario for 25,354 p.e. of reported load: 1,012,666 kWh per year (39.9 kWh per p.e. of average load), with aeration as 59 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.