WWTP GRAND-CHAMP KERMEHEN

France · official identifier FR0456067S0001

7,500h-e design capacity (2022) · 1679th of 4,051 (tied with 41 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier FR0456067S0001 · reported size 7,500 h-e design capacity · received load 5,742 h-e · reported treatment: PST · data year 2022. 1679th of 4,051 records with reported size in the inventory of France (tied with 41 others); < 0.01 % of the sum of those 4,051 records in h-e (sum of records, not national capacity); nearest inventoried plant at 5.6 km · 3 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

7,500h-e design capacity
5,742h-e received load (2022)
77 %reported load/capacity ratio (not hydraulic utilisation)
1679th of 4,051by reported size among the 4,051 records with a size in the inventory (tied with 41 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates47.7670, -2.8510 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: France

Regulatory framework of France · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

236,298reference kWh per year for this load
41.1kWh per h-e (average load) per year
35,445€ per year at 0.15 €/kWh
52 %share of energy used for aeration

what this estimate is · Inputs: 5,742 p.e. of reported load; equivalent average load 5,748 p.e. with the reference profile of France (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.3estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (833 m³/day of reference), not measured or available for reclamation.

LOCATION

France: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Locmaria-Grand-Champ Collec5.6 km6,0002,224primary, secondary and tertiary
Meucon les Marais7.6 km5,0002,932primary, secondary and tertiary
Plescop Le Moustoir9.7 km6,0005,300primary, secondary and tertiary
Saint-Ave Lesvellec10.6 km6,6005,088primary, secondary and tertiary
Ploeren les Deux Moulins11.9 km5,0004,103primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP GRAND-CHAMP KERMEHEN report?

Reported size: 7,500 h-e design capacity. Received load: 5,742 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of GRAND-CHAMP KERMEHEN?

Aguas SB simulator reference scenario for 5,742 p.e. of reported load: 236,298 kWh per year (41.1 kWh per p.e. of average load), with aeration as 52 % of consumption. Estimate with the country reference profile; not a measurement of the plant.