Worldwide wastewater treatment observatory · France

Aguas SB Observatory · public data to understand water

WWTP LMM_LE MANS - LA CHAUVINIÈRE

France · official identifier FR0472181S0016

365,000h-e design capacity (2022) · 31st of 4,051

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier FR0472181S0016 · reported size 365,000 h-e design capacity · received load 247,909 h-e · reported treatment: PST · data year 2022. 31st of 4,051 records with reported size in the inventory of France; 0.37 % of the sum of those 4,051 records in h-e (sum of records, not national capacity); nearest inventoried plant at 6.0 km · 7 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

365,000h-e design capacity
247,909h-e received load (2022)
68 %reported load/capacity ratio (not hydraulic utilisation)
31st of 4,051by reported size among the 4,051 records with a size in the inventory · 0.37 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates47.9821, 0.1703 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

FUENTES PÚBLICAS

What public sources report

Documented milestones

Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L02; it does not change the official data.

REGULATORY REFERENCES

Referencia normativa: France

Regulatory framework of France · Directive (EU) 2024/3019: reported-capacity band 150,000 p.e. or more; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

6,926,950reference kWh per year for this load
27.9kWh per h-e (average load) per year
1,039,043€ per year at 0.15 €/kWh
65 %share of energy used for aeration

what this estimate is · Inputs: 247,909 p.e. of reported load; equivalent average load 248,034 p.e. with the reference profile of France (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

13.1estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (35,947 m³/day of reference), not measured or available for reclamation.

LOCATION

France: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Lmm-Saint-Georges-Du-Bois - Etival-les-Lemans6.0 km4,0002,300primary, secondary and tertiary
Lmm-Ruaudin - les Queutes6.7 km7,5003,715primary, secondary and tertiary
Spay - Rte de Fillé7.1 km3,5002,140primary, secondary and tertiary
Lmm_saint-Saturnin - la Milesse - Aigne7.7 km8,2008,577primary, secondary and tertiary
Change - Route D'Yvré8.9 km5,3334,421primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP LMM_LE MANS - LA CHAUVINIÈRE report?

Reported size: 365,000 h-e design capacity. Received load: 247,909 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of LMM_LE MANS - LA CHAUVINIÈRE?

Aguas SB simulator reference scenario for 247,909 p.e. of reported load: 6,926,950 kWh per year (27.9 kWh per p.e. of average load), with aeration as 65 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.