Worldwide wastewater treatment observatory · France

Aguas SB Observatory · public data to understand water

WWTP LONGNY-AU-PERCHE

France · official identifier FR036123002000

2,050h-e design capacity (2022) · 3789th of 4,051 (tied with 1 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier FR036123002000 · reported size 2,050 h-e design capacity · received load 1,810 h-e · reported treatment: PST · data year 2022. 3789th of 4,051 records with reported size in the inventory of France (tied with 1 others); < 0.01 % of the sum of those 4,051 records in h-e (sum of records, not national capacity); nearest inventoried plant at 15.5 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

2,050h-e design capacity
1,810h-e received load (2022)
88 %reported load/capacity ratio (not hydraulic utilisation)
3789th of 4,051by reported size among the 4,051 records with a size in the inventory (tied with 1 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates48.5260, 0.7517 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: France

Regulatory framework of France · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

85,384reference kWh per year for this load
47.2kWh per h-e (average load) per year
12,808€ per year at 0.15 €/kWh
71 %share of energy used for aeration

what this estimate is · Inputs: 1,810 p.e. of reported load; equivalent average load 1,808 p.e. with the reference profile of France (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (262 m³/day of reference), not measured or available for reclamation.

LOCATION

France: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Mortagne-Au-Perche Saint-Langis-les-Mortagne15.5 km12,0006,784primary, secondary and tertiary
Loupe19.7 km6,0003,753primary, secondary and tertiary
Senonches21.8 km5,0002,067primary, secondary and tertiary
Saint-Martin-Du-Vieux-Belleme 200722.8 km9,0003,490primary, secondary and tertiary
Nogent-Le-Rotrou23.6 km29,00016,017primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP LONGNY-AU-PERCHE report?

Reported size: 2,050 h-e design capacity. Received load: 1,810 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of LONGNY-AU-PERCHE?

Aguas SB simulator reference scenario for 1,810 p.e. of reported load: 85,384 kWh per year (47.2 kWh per p.e. of average load), with aeration as 71 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.