Worldwide wastewater treatment observatory · Germany

Aguas SB Observatory · public data to understand water

WWTP 1010002017 KA Braunschweig

Germany · official identifier DETP_NI101000201

275,000h-e design capacity (2022) · 76th of 3,798 (tied with 1 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier DETP_NI101000201 · reported size 275,000 h-e design capacity · received load 400,000 h-e · reported treatment: PST · data year 2022. 76th of 3,798 records with reported size in the inventory of Germany (tied with 1 others); 0.19 % of the sum of those 3,798 records in h-e (sum of records, not national capacity); nearest inventoried plant at 6.7 km · 1 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

275,000h-e design capacity
400,000h-e received load (2022)
145 %reported load/capacity ratio (not hydraulic utilisation)
76th of 3,798by reported size among the 3,798 records with a size in the inventory (tied with 1 others) · 0.19 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates52.3217, 10.4444 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

FUENTES PÚBLICAS

What public sources report

Documented milestones

  • 1979 · Since 1979, the Braunschweig infiltration fields have received only treated wastewater from the Steinhof plant. City of Braunschweig

Other published data

Mean annual volume treated reported in the 2022 cycle16,995,800 m³/year (2022) · source

Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L03; it does not change the official data.

REGULATORY REFERENCES

Referencia normativa: Germany

Regulatory framework of Germany · Directive (EU) 2024/3019: reported-capacity band 150,000 p.e. or more; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

11,568,837reference kWh per year for this load
28.9kWh per h-e (average load) per year
1,735,326€ per year at 0.15 €/kWh
61 %share of energy used for aeration

what this estimate is · Inputs: 400,000 p.e. of reported load; equivalent average load 400,320 p.e. with the reference profile of Germany (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

31.5estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (86,400 m³/day of reference), not measured or available for reclamation.

LOCATION

Germany: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
1570072002 Ka Wahle6.7 km19,50020,900primary, secondary and tertiary
1570092012 Ka Münstedt13.1 km4,0003,294primary and secondary
1570012003 Ka Edemissen13.7 km8,8006,361primary, secondary and tertiary
1580062023 Ka Weddel13.9 km10,5006,245primary, secondary and tertiary
1540142031 Ka Lehre14.1 km16,50011,517primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP 1010002017 KA Braunschweig report?

Reported size: 275,000 h-e design capacity. Received load: 400,000 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of 1010002017 KA Braunschweig?

Aguas SB simulator reference scenario for 400,000 p.e. of reported load: 11,568,837 kWh per year (28.9 kWh per p.e. of average load), with aeration as 61 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.