Worldwide wastewater treatment observatory · Germany

Aguas SB Observatory · public data to understand water

WWTP 2510402010 KA Sulingen

Germany · official identifier DETP_NI251040201

21,000h-e design capacity (2022) · 1339th of 3,798 (tied with 16 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier DETP_NI251040201 · reported size 21,000 h-e design capacity · received load 13,120 h-e · reported treatment: PST · data year 2022. 1339th of 3,798 records with reported size in the inventory of Germany (tied with 16 others); 0.01 % of the sum of those 3,798 records in h-e (sum of records, not national capacity); nearest inventoried plant at 8.1 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

21,000h-e design capacity
13,120h-e received load (2022)
62 %reported load/capacity ratio (not hydraulic utilisation)
1339th of 3,798by reported size among the 3,798 records with a size in the inventory (tied with 16 others) · 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates52.6711, 8.8029 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Germany

Regulatory framework of Germany · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

583,034reference kWh per year for this load
44.4kWh per h-e (average load) per year
87,455€ per year at 0.15 €/kWh
47 %share of energy used for aeration

what this estimate is · Inputs: 13,120 p.e. of reported load; equivalent average load 13,131 p.e. with the reference profile of Germany (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

1estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (2,834 m³/day of reference), not measured or available for reclamation.

LOCATION

Germany: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
2514042009 Ka Kirchdorf8.1 km5,0003,797primary, secondary and tertiary
2514072014 Ka Siedenburg8.5 km7,5008,654primary, secondary and tertiary
2514072008 Ka Ehrenburg10.0 km3,0002,096primary, secondary and tertiary
2510422015 Ka Twistringen17.5 km20,00018,647primary, secondary and tertiary
2560302034 Ka Steyerberg18.6 km9,0003,820primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP 2510402010 KA Sulingen report?

Reported size: 21,000 h-e design capacity. Received load: 13,120 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of 2510402010 KA Sulingen?

Aguas SB simulator reference scenario for 13,120 p.e. of reported load: 583,034 kWh per year (44.4 kWh per p.e. of average load), with aeration as 47 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.