Worldwide wastewater treatment observatory · Germany

Aguas SB Observatory · public data to understand water

WWTP 2530012129 KA Barsinghausen

Germany · official identifier DETP_NI253001201

67,000h-e design capacity (2022) · 435th of 3,798 (tied with 3 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier DETP_NI253001201 · reported size 67,000 h-e design capacity · received load 37,200 h-e · reported treatment: PST · data year 2022. 435th of 3,798 records with reported size in the inventory of Germany (tied with 3 others); 0.05 % of the sum of those 3,798 records in h-e (sum of records, not national capacity); nearest inventoried plant at 7.5 km · 3 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

67,000h-e design capacity
37,200h-e received load (2022)
56 %reported load/capacity ratio (not hydraulic utilisation)
435th of 3,798by reported size among the 3,798 records with a size in the inventory (tied with 3 others) · 0.05 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates52.3475, 9.5029 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Germany

Regulatory framework of Germany · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,552,046reference kWh per year for this load
41.7kWh per h-e (average load) per year
232,807€ per year at 0.15 €/kWh
54 %share of energy used for aeration

what this estimate is · Inputs: 37,200 p.e. of reported load; equivalent average load 37,229 p.e. with the reference profile of Germany (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

2.9estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (8,035 m³/day of reference), not measured or available for reclamation.

LOCATION

Germany: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
2574032010 Ka Haste7.5 km8,5004,467primary, secondary and tertiary
2530142095 Ka Gümmerwald7.6 km750,000600,983primary, secondary and tertiary
2574032011 Ka Bad Nenndorf8.7 km21,00013,333primary, secondary and tertiary
2530202128 Ka Wunstorf10.6 km77,50060,583primary, secondary and tertiary
2530192164 Ka Evestorf11.6 km17,50016,769primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP 2530012129 KA Barsinghausen report?

Reported size: 67,000 h-e design capacity. Received load: 37,200 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of 2530012129 KA Barsinghausen?

Aguas SB simulator reference scenario for 37,200 p.e. of reported load: 1,552,046 kWh per year (41.7 kWh per p.e. of average load), with aeration as 54 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.