Worldwide wastewater treatment observatory · Germany

Aguas SB Observatory · public data to understand water

WWTP 4570132015 KA Leer

Germany · official identifier DETP_NI457013201

95,000h-e design capacity (2022) · 271st of 3,798 (tied with 14 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier DETP_NI457013201 · reported size 95,000 h-e design capacity · received load 47,250 h-e · reported treatment: PST · data year 2022. 271st of 3,798 records with reported size in the inventory of Germany (tied with 14 others); 0.06 % of the sum of those 3,798 records in h-e (sum of records, not national capacity); nearest inventoried plant at 7.6 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

95,000h-e design capacity
47,250h-e received load (2022)
50 %reported load/capacity ratio (not hydraulic utilisation)
271st of 3,798by reported size among the 3,798 records with a size in the inventory (tied with 14 others) · 0.06 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates53.2285, 7.4284 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Germany

Regulatory framework of Germany · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,879,479reference kWh per year for this load
39.7kWh per h-e (average load) per year
281,922€ per year at 0.15 €/kWh
54 %share of energy used for aeration

what this estimate is · Inputs: 47,250 p.e. of reported load; equivalent average load 47,288 p.e. with the reference profile of Germany (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

3.7estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (10,206 m³/day of reference), not measured or available for reclamation.

LOCATION

Germany: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
4570212003 Ka Weener7.6 km20,00015,856primary, secondary and tertiary
4570142009 Ka Neermoor7.7 km15,75017,502primary, secondary and tertiary
4574012014 Ka Bunde11.8 km11,2007,683primary, secondary and tertiary
4570222001 Ka Steenfelde12.2 km25,00020,782primary, secondary and tertiary
4570142008 Ka Oldersum12.8 km4,0002,115primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP 4570132015 KA Leer report?

Reported size: 95,000 h-e design capacity. Received load: 47,250 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of 4570132015 KA Leer?

Aguas SB simulator reference scenario for 47,250 p.e. of reported load: 1,879,479 kWh per year (39.7 kWh per p.e. of average load), with aeration as 54 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.