Worldwide wastewater treatment observatory · Greece

Aguas SB Observatory · public data to understand water

WWTP CHALKIDA

Greece · official identifier EL242001016

111,600h-e design capacity (2022) · 15th of 273

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier EL242001016 · reported size 111,600 h-e design capacity · received load 66,362 h-e · reported treatment: PST · data year 2022. 15th of 273 records with reported size in the inventory of Greece; 0.77 % of the sum of those 273 records in h-e (sum of records, not national capacity); nearest inventoried plant at 12.3 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

111,600h-e design capacity
66,362h-e received load (2022)
59 %reported load/capacity ratio (not hydraulic utilisation)
15th of 273by reported size among the 273 records with a size in the inventory · 0.77 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates38.4449, 23.6047 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

FUENTES PÚBLICAS

What public sources report

Documented milestones

Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L07; it does not change the official data.

REGULATORY REFERENCES

Referencia normativa: Greece

Regulatory framework of Greece · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

2,377,887reference kWh per year for this load
35.8kWh per h-e (average load) per year
356,683€ per year at 0.15 €/kWh
58 %share of energy used for aeration

what this estimate is · Inputs: 66,362 p.e. of reported load; equivalent average load 66,365 p.e. with the reference profile of Greece (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

4.3estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (11,746 m³/day of reference), not measured or available for reclamation.

LOCATION

Greece: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Nea Artaki12.3 km12,0009,746primary, secondary and tertiary
Inofyta-Schimatari14.9 km20,0008,000primary, secondary and tertiary
Thiva25.6 km40,00024,226primary, secondary and tertiary
Amarynthos26.4 km16,20012,800primary, secondary and tertiary
Erythres33.7 km6,6002,822primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP CHALKIDA report?

Reported size: 111,600 h-e design capacity. Received load: 66,362 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of CHALKIDA?

Aguas SB simulator reference scenario for 66,362 p.e. of reported load: 2,377,887 kWh per year (35.8 kWh per p.e. of average load), with aeration as 58 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.