Worldwide wastewater treatment observatory · Hungary

Aguas SB Observatory · public data to understand water

WWTP Balatonfuzfo - Szennyviztisztito Telep

Hungary · official identifier HU-WWTP-AIA347

49,174h-e design capacity (2022) · 53rd of 829

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier HU-WWTP-AIA347 · reported size 49,174 h-e design capacity · received load 40,000 h-e · reported treatment: PST · data year 2022. 53rd of 829 records with reported size in the inventory of Hungary; 0.33 % of the sum of those 829 records in h-e (sum of records, not national capacity); nearest inventoried plant at 2.3 km · 3 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

49,174h-e design capacity
40,000h-e received load (2022)
81 %reported load/capacity ratio (not hydraulic utilisation)
53rd of 829by reported size among the 829 records with a size in the inventory · 0.33 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates47.0923, 18.0470 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Hungary

Regulatory framework of Hungary · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,279,334reference kWh per year for this load
36.1kWh per h-e (average load) per year
191,900€ per year at 0.15 €/kWh
63 %share of energy used for aeration

what this estimate is · Inputs: 40,000 p.e. of reported load; equivalent average load 35,476 p.e. with the reference profile of Hungary (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

1.4estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (3,920 m³/day of reference), not measured or available for reclamation.

LOCATION

Hungary: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Kiralyszentistvan - Szennyviztisztito Telep2.3 km4,9403,870primary, secondary and tertiary
Berhida - Szennyviztisztito Telep7.7 km9,6009,200primary, secondary and tertiary
Osku - Szennyviztisztito Telep8.8 km1,7502,243primary, secondary and tertiary
Veszprem - Szennyviztisztito Telep10.7 km122,373112,522primary, secondary and tertiary
Petfurdo - Szennyviztisztito Telep (Nitrogenmuvek Zrt. Szv.T10.8 km8,0005,010primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Balatonfuzfo - Szennyviztisztito Telep report?

Reported size: 49,174 h-e design capacity. Received load: 40,000 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Balatonfuzfo - Szennyviztisztito Telep?

Aguas SB simulator reference scenario for 40,000 p.e. of reported load: 1,279,334 kWh per year (36.1 kWh per p.e. of average load), with aeration as 63 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source