Worldwide wastewater treatment observatory · Hungary

Aguas SB Observatory · public data to understand water

WWTP Bocs - Szennyviztisztito Telep

Hungary · official identifier HU-WWTP-AHZ121

2,700h-e design capacity (2022) · 503rd of 829 (tied with 3 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier HU-WWTP-AHZ121 · reported size 2,700 h-e design capacity · received load 2,389 h-e · reported treatment: PST · data year 2022. 503rd of 829 records with reported size in the inventory of Hungary (tied with 3 others); 0.02 % of the sum of those 829 records in h-e (sum of records, not national capacity); nearest inventoried plant at 3.9 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

2,700h-e design capacity
2,389h-e received load (2022)
88 %reported load/capacity ratio (not hydraulic utilisation)
503rd of 829by reported size among the 829 records with a size in the inventory (tied with 3 others) · 0.02 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates48.0406, 20.9844 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Hungary

Regulatory framework of Hungary · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

94,803reference kWh per year for this load
44.8kWh per h-e (average load) per year
14,221€ per year at 0.15 €/kWh
74 %share of energy used for aeration

what this estimate is · Inputs: 2,389 p.e. of reported load; equivalent average load 2,118 p.e. with the reference profile of Hungary (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (234 m³/day of reference), not measured or available for reclamation.

LOCATION

Hungary: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Tiszaluc - Szennyviztisztito Telep3.9 km4,2333,861primary, secondary and tertiary
Korom - Szennyviztisztito Telep7.4 km14,92517,902primary, secondary and tertiary
Miskolc - Szennyviztisztito Telep11.2 km350,000186,408primary, secondary and tertiary
Szakald - Szennyviztisztito Telep11.8 km300335primary, secondary and tertiary
Ocsanalos - Szennyviztisztito Telep11.9 km200250primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Bocs - Szennyviztisztito Telep report?

Reported size: 2,700 h-e design capacity. Received load: 2,389 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Bocs - Szennyviztisztito Telep?

Aguas SB simulator reference scenario for 2,389 p.e. of reported load: 94,803 kWh per year (44.8 kWh per p.e. of average load), with aeration as 74 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.