Worldwide wastewater treatment observatory · Hungary

Aguas SB Observatory · public data to understand water

WWTP Kecskemet - Szennyviztisztito Telep

Hungary · official identifier HU-WWTP-AIB815

240,000h-e design capacity (2022) · 8th of 829

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier HU-WWTP-AIB815 · reported size 240,000 h-e design capacity · received load 235,118 h-e · reported treatment: PS · data year 2022. 8th of 829 records with reported size in the inventory of Hungary; 1.6 % of the sum of those 829 records in h-e (sum of records, not national capacity); nearest inventoried plant at 12.6 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

240,000h-e design capacity
235,118h-e received load (2022)
98 %reported load/capacity ratio (not hydraulic utilisation)
8th of 829by reported size among the 829 records with a size in the inventory · 1.6 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates46.8927, 19.7144 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

FUENTES PÚBLICAS

What public sources report

Documented milestones

Other published data

Mean annual volume treated reported in the 2022 cycle6,989,200 m³/year (2022) · source

Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L03; it does not change the official data.

REGULATORY REFERENCES

Referencia normativa: Hungary

Regulatory framework of Hungary · Directive (EU) 2024/3019: reported-capacity band 150,000 p.e. or more; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

5,539,243reference kWh per year for this load
26.6kWh per h-e (average load) per year
830,886€ per year at 0.15 €/kWh
67 %share of energy used for aeration

what this estimate is · Inputs: 235,118 p.e. of reported load; equivalent average load 208,530 p.e. with the reference profile of Hungary (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

8.4estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (23,042 m³/day of reference), not measured or available for reclamation.

LOCATION

Hungary: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Nyarlorinc - Szennyviztisztito Telep12.6 km2,2001,824primary, secondary and tertiary
Szentkiraly Szennyviztisztito Telep15.9 km1,984955primary and secondary
Jakabszallas - Szennyviztisztito Telep15.9 km2,1992,200primary and secondary
Nagykoros - Szennyviztisztito Telep17.7 km25,00018,910primary and secondary
Lajosmizse - Szennyviztisztito Telep20.9 km10,00411,323primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Kecskemet - Szennyviztisztito Telep report?

Reported size: 240,000 h-e design capacity. Received load: 235,118 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Kecskemet - Szennyviztisztito Telep?

Aguas SB simulator reference scenario for 235,118 p.e. of reported load: 5,539,243 kWh per year (26.6 kWh per p.e. of average load), with aeration as 67 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source