Worldwide wastewater treatment observatory · Iceland

Aguas SB Observatory · public data to understand water

WWTP Höfuðborgarsvæðið, Ánanaust

Iceland · official identifier IS001-01

170,000h-e design capacity (2022) · 2nd of 22

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IS001-01 · reported size 170,000 h-e design capacity · received load 117,763 h-e · reported treatment: T · data year 2022. 2nd of 22 records with reported size in the inventory of Iceland; 22.0 % of the sum of those 22 records in h-e (sum of records, not national capacity); nearest inventoried plant at 4.0 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

170,000h-e design capacity
117,763h-e received load (2022)
69 %reported load/capacity ratio (not hydraulic utilisation)
2nd of 22by reported size among the 22 records with a size in the inventory · 22.0 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentterciario (más riguroso) (as reported to the EEA: T) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates64.1530, -21.9551 precision reported by the source: level 1 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

FUENTES PÚBLICAS

What public sources report

Documented milestones

  • 1998 · The Ánanaust wastewater treatment plant in Reykjavík entered service in 1998. City of Reykjavík

Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L05; it does not change the official data.

REGULATORY REFERENCES

Referencia normativa: Iceland

Regulatory framework of Iceland. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

3,887,656reference kWh per year for this load
33.0kWh per h-e (average load) per year
583,148€ per year at 0.15 €/kWh
56 %share of energy used for aeration

what this estimate is · Inputs: 117,763 p.e. of reported load; equivalent average load 117,765 p.e. with the reference profile of Iceland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

8.6estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (23,553 m³/day of reference), not measured or available for reclamation.

LOCATION

Iceland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Höfuðborgarsvæðið, Klettagarðar4.0 km285,000205,743not reported
Alftanes6.2 km3,0002,530not reported
Hraunavík, Hafnarfjörður11.7 km60,00048,928not reported
Akranes20.2 km35,00086,285not reported
Keflavik34.3 kmnot reported16,226not reported

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Höfuðborgarsvæðið, Ánanaust report?

Reported size: 170,000 h-e design capacity. Received load: 117,763 h-e. Units are retained without conversion.

What treatment is reported?

Treatment T. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Höfuðborgarsvæðið, Ánanaust?

Aguas SB simulator reference scenario for 117,763 p.e. of reported load: 3,887,656 kWh per year (33.0 kWh per p.e. of average load), with aeration as 56 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.