Worldwide wastewater treatment observatory · Italy

Aguas SB Observatory · public data to understand water

WWTP COL_VALLE_ACQUA_GIULIA

Italy · official identifier IT11Q230000002

not reportedh-e design capacity (2022)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT11Q230000002 · reported size not reported h-e design capacity · received load 1,825 h-e · data year 2022. nearest inventoried plant at 1.1 km · 4 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

not reportedh-e design capacity
1,825h-e received load (2022)
not reportedsin tamaño declarado · the largest plants in the country
Treatmentnot reported
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates43.4384, 13.3438 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

69,909reference kWh per year for this load
55.5kWh per h-e (average load) per year
10,486€ per year at 0.15 €/kWh
62 %share of energy used for aeration

what this estimate is · Inputs: 1,825 p.e. of reported load; equivalent average load 1,259 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (365 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Col_rio_fiele1.1 kmnot reported1,814not reported
Comunale_filottrano_dep3.6 km11,7002,530primary, secondary and tertiary
Santa_maria_nuova_dep5.4 km2,5003,439primary, secondary and tertiary
Verdefiore_app_dep8.1 km4,5003,027primary, secondary and tertiary
Cerrete_colicelli_cin_dep12.1 km5,0005,528primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP COL_VALLE_ACQUA_GIULIA report?

Reported size: not reported h-e design capacity. Received load: 1,825 h-e. Units are retained without conversion.

What treatment is reported?

Treatment not reported. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of COL_VALLE_ACQUA_GIULIA?

Aguas SB simulator reference scenario for 1,825 p.e. of reported load: 69,909 kWh per year (55.5 kWh per p.e. of average load), with aeration as 62 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source