Worldwide wastewater treatment observatory · Italy

Aguas SB Observatory · public data to understand water

WWTP COSSATO SPOLINA

Italy · official identifier IT01000000000026

520,000h-e design capacity (2022) · 27th of 3,726

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT01000000000026 · reported size 520,000 h-e design capacity · received load 114,123 h-e · reported treatment: PS · data year 2022. 27th of 3,726 records with reported size in the inventory of Italy; 0.50 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 7.0 km · 1 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

520,000h-e design capacity
114,123h-e received load (2022)
22 %reported load/capacity ratio (not hydraulic utilisation)
27th of 3,726by reported size among the 3,726 records with a size in the inventory · 0.50 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates45.5444, 8.1829 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

FUENTES PÚBLICAS

What public sources report

Documented milestones

Other published data

Mean annual volume treated reported in the 2022 cycle14,852,906 m³/year (2022) · source

Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L02; it does not change the official data.

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 150,000 p.e. or more; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

3,206,808reference kWh per year for this load
40.7kWh per h-e (average load) per year
481,021€ per year at 0.15 €/kWh
50 %share of energy used for aeration

what this estimate is · Inputs: 114,123 p.e. of reported load; equivalent average load 78,746 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

8.3estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (22,825 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Massazza7.0 km37,00027,955primary and secondary
Biella Sud - Ponderano11.0 km53,00010,292primary and secondary
Biella Nord11.0 km67,00036,494primary and secondary
Cerrione11.0 km11,0009,946primary and secondary
Gattinara16.4 km10,0009,512primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP COSSATO SPOLINA report?

Reported size: 520,000 h-e design capacity. Received load: 114,123 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of COSSATO SPOLINA?

Aguas SB simulator reference scenario for 114,123 p.e. of reported load: 3,206,808 kWh per year (40.7 kWh per p.e. of average load), with aeration as 50 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.