WWTP Depuratore urbano Ardea-MONTAGNANO
Italy · official identifier IT12Q17100000001
90,000h-e design capacity (2022) · 201st of 3,726 (tied with 20 others)
European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT12Q17100000001 · reported size 90,000 h-e design capacity · received load 85,500 h-e · reported treatment: PST · data year 2022. 201st of 3,726 records with reported size in the inventory of Italy (tied with 20 others); 0.09 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 5.3 km · 5 within 10 km. Reported data with their source; estimates are not measurements of the plant.
Aguas SB does not manage this wastewater treatment plant.
WHAT THE DATA REPORT
Reported data official data · 2022
| Treatment | primary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels |
|---|---|
| Nitrogen removal | not reported |
| Phosphorus removal | not reported |
| UV disinfection | not reported |
| Status | active |
| Reported coordinates | 41.6736, 12.6314 precision reported by the source: level 2 what it means |
| Source and year | European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record |
REGULATORY REFERENCES
Referencia normativa: Italy
Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.
SCENARIO
Reference energy scenario for this load estimate · simulator engine
what this estimate is · Inputs: 85,500 p.e. of reported load; equivalent average load 58,995 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.
Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.
WATER THAT COULD RETURN
Reuse potential
what this estimate is · Volume estimated from the reported load (17,100 m³/day of reference), not measured or available for reclamation.
NEARBY PLANTS
Nearby wastewater treatment plants
| Plant | Distance | Capacity (h-e) | Load 2022 | Treatment |
|---|---|---|---|---|
| Dep_com_pietrara | 5.3 km | 6,300 | 5,985 | primary, secondary and tertiary |
| Depuratore Urbano Pomezia-Santa Palomba | 6.3 km | 1,700 | 1,615 | primary and secondary |
| Santa_fumia | 7.6 km | 3,000 | 2,850 | primary, secondary and tertiary |
| Dep_com_pavona | 9.4 km | 45,000 | 42,750 | primary, secondary and tertiary |
| Dep_com_sughereto_pomezia_centro | 10.5 km | 60,000 | 57,000 | primary, secondary and tertiary |
Distances are between reported coordinates; proximity does not establish a hydraulic connection.
QUESTIONS
Frequently asked questions about this plant
What capacity does WWTP Depuratore urbano Ardea-MONTAGNANO report?
Reported size: 90,000 h-e design capacity. Received load: 85,500 h-e. Units are retained without conversion.
What treatment is reported?
Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.
How much energy would a reference plant use with the load of Depuratore urbano Ardea-MONTAGNANO?
Aguas SB simulator reference scenario for 85,500 p.e. of reported load: 2,547,409 kWh per year (43.2 kWh per p.e. of average load), with aeration as 50 % of consumption. Estimate with the country reference profile; not a measurement of the plant.
SOURCE AND CORRECTIONS
Source
reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.