Worldwide wastewater treatment observatory · Italy

Aguas SB Observatory · public data to understand water

WWTP DP01501101_Assago

Italy · official identifier IT03160128000441

160,000h-e design capacity (2022) · 103rd of 3,726 (tied with 3 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT03160128000441 · reported size 160,000 h-e design capacity · received load 120,948 h-e · reported treatment: PST · data year 2022. 103rd of 3,726 records with reported size in the inventory of Italy (tied with 3 others); 0.15 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 2.4 km · 11 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

160,000h-e design capacity
120,948h-e received load (2022)
76 %reported load/capacity ratio (not hydraulic utilisation)
103rd of 3,726by reported size among the 3,726 records with a size in the inventory (tied with 3 others) · 0.15 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates45.3992, 9.1393 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 150,000 p.e. or more; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

3,358,566reference kWh per year for this load
40.2kWh per h-e (average load) per year
503,785€ per year at 0.15 €/kWh
50 %share of energy used for aeration

what this estimate is · Inputs: 120,948 p.e. of reported load; equivalent average load 83,456 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

8.8estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (24,190 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Dp01518901_rozzano2.4 km122,40056,157primary, secondary and tertiary
Dp01514602_milano_s_rocco3.5 km1,050,000750,863primary, secondary and tertiary
Dp01522001_trezzano_sul_naviglio4.4 km52,00035,541primary, secondary and tertiary
Dp01501501_basiglio5.4 km16,3009,048primary, secondary and tertiary
Dp01514601_milano_nosedo7.1 km1,250,0001,116,928primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP DP01501101_Assago report?

Reported size: 160,000 h-e design capacity. Received load: 120,948 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of DP01501101_Assago?

Aguas SB simulator reference scenario for 120,948 p.e. of reported load: 3,358,566 kWh per year (40.2 kWh per p.e. of average load), with aeration as 50 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.