Worldwide wastewater treatment observatory · Italy

Aguas SB Observatory · public data to understand water

WWTP DP01902101_Casalmaggiore_Vicomoscano

Italy · official identifier IT03160129000676

48,000h-e design capacity (2022) · 415th of 3,726 (tied with 1 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT03160129000676 · reported size 48,000 h-e design capacity · received load 26,321 h-e · reported treatment: PST · data year 2022. 415th of 3,726 records with reported size in the inventory of Italy (tied with 1 others); 0.05 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 6.8 km · 5 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

48,000h-e design capacity
26,321h-e received load (2022)
55 %reported load/capacity ratio (not hydraulic utilisation)
415th of 3,726by reported size among the 3,726 records with a size in the inventory (tied with 1 others) · 0.05 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionyes
Statusactive
Reported coordinates44.9853, 10.4514 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

920,573reference kWh per year for this load
50.7kWh per h-e (average load) per year
138,086€ per year at 0.15 €/kWh
43 %share of energy used for aeration

what this estimate is · Inputs: 26,321 p.e. of reported load; equivalent average load 18,161 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

1.9estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (5,264 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Dp02006602_viadana6.8 km13,00016,540primary, secondary and tertiary
Colorno_nord8.0 km2,8002,785primary, secondary and tertiary
Colorno8.2 km5,7005,521primary, secondary and tertiary
Mezzani_mezzano_inferiore8.2 km9,6003,767primary, secondary and tertiary
Dp02005002_rivarolo_mantovano8.8 km3,0002,546primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP DP01902101_Casalmaggiore_Vicomoscano report?

Reported size: 48,000 h-e design capacity. Received load: 26,321 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of DP01902101_Casalmaggiore_Vicomoscano?

Aguas SB simulator reference scenario for 26,321 p.e. of reported load: 920,573 kWh per year (50.7 kWh per p.e. of average load), with aeration as 43 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.