Worldwide wastewater treatment observatory · Italy

Aguas SB Observatory · public data to understand water

WWTP IMPIANTO_C_DA_FONDACAZZO_FRAZ_VILLASMUNDO

Italy · official identifier IT19SR00G0012DE001

3,015h-e design capacity (2022) · 2500th of 3,726

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT19SR00G0012DE001 · reported size 3,015 h-e design capacity · received load 2,975 h-e · reported treatment: PT · data year 2022. 2500th of 3,726 records with reported size in the inventory of Italy; < 0.01 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 7.4 km · 4 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

3,015h-e design capacity
2,975h-e received load (2022)
99 %reported load/capacity ratio (not hydraulic utilisation)
2500th of 3,726by reported size among the 3,726 records with a size in the inventory · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + tertiary (more stringent) (as reported to the EEA: PT) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates37.2184, 15.1030 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Regulatory reference: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

109,302reference kWh per year for this load
53.2kWh per h-e (average load) per year
16,395€ per year at 0.15 €/kWh
64 %share of energy used for aeration

what this estimate is · Inputs: 2,975 p.e. of reported load; equivalent average load 2,053 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.2estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (595 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Sistema_di_collettamento_sortino8.9 kmnot reportednot reportednot reported
Impianto_c_da_costa_fiume-Imprimo9.6 km12,0009,294primary
Sistema_di_collettamento_brucoli9.7 kmnot reportednot reportednot reported
Sistema_di_collettamento_augusta11.4 kmnot reportednot reportednot reported
Impianto_c_da_magnisi_casale_vecchie_saline_depuratore_ias_p12.0 km750,00034,520primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP IMPIANTO_C_DA_FONDACAZZO_FRAZ_VILLASMUNDO report?

Reported size: 3,015 h-e design capacity. Received load: 2,975 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PT. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of IMPIANTO_C_DA_FONDACAZZO_FRAZ_VILLASMUNDO?

Aguas SB simulator reference scenario for 2,975 p.e. of reported load: 109,302 kWh per year (53.2 kWh per p.e. of average load), with aeration as 64 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.