Worldwide wastewater treatment observatory · Italy

Aguas SB Observatory · public data to understand water

WWTP IMPIANTO C.DA S.ANNA

Italy · official identifier IT19AG00G0023DE001

55,000h-e design capacity (2022) · 358th of 3,726 (tied with 10 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT19AG00G0023DE001 · reported size 55,000 h-e design capacity · received load 49,970 h-e · reported treatment: PS · data year 2022. 358th of 3,726 records with reported size in the inventory of Italy (tied with 10 others); 0.05 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 2.4 km · 8 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

55,000h-e design capacity
49,970h-e received load (2022)
91 %reported load/capacity ratio (not hydraulic utilisation)
358th of 3,726by reported size among the 3,726 records with a size in the inventory (tied with 10 others) · 0.05 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates37.2992, 13.5750 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,658,279reference kWh per year for this load
48.1kWh per h-e (average load) per year
248,742€ per year at 0.15 €/kWh
50 %share of energy used for aeration

what this estimate is · Inputs: 49,970 p.e. of reported load; equivalent average load 34,479 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

3.6estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (9,994 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Sistema Di Collettamento Agrigento2.4 kmnot reportednot reportednot reported
Impianto C.Da Fontanelle3.7 km11,0009,614primary and secondary
Impianto Via Molo Levante4.0 km33,00028,841primary and secondary
Sistema Di Collettamento Porto Empedocle4.3 kmnot reportednot reportednot reported
Impianto C.Da Burgialamone-Chimento6.1 km35,00035,000primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP IMPIANTO C.DA S.ANNA report?

Reported size: 55,000 h-e design capacity. Received load: 49,970 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of IMPIANTO C.DA S.ANNA?

Aguas SB simulator reference scenario for 49,970 p.e. of reported load: 1,658,279 kWh per year (48.1 kWh per p.e. of average load), with aeration as 50 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.