WWTP Limena_Via_A_Volta

Italy · official identifier IT05000000000239

20,000h-e design capacity (2022) · 840th of 3,726 (tied with 62 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT05000000000239 · reported size 20,000 h-e design capacity · received load 15,851 h-e · reported treatment: PST · data year 2022. 840th of 3,726 records with reported size in the inventory of Italy (tied with 62 others); 0.02 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 4.0 km · 5 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

20,000h-e design capacity
15,851h-e received load (2022)
79 %reported load/capacity ratio (not hydraulic utilisation)
840th of 3,726by reported size among the 3,726 records with a size in the inventory (tied with 62 others) · 0.02 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates45.4660, 11.8610 precision reported by the source: level 1 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

561,116reference kWh per year for this load
51.3kWh per h-e (average load) per year
84,167€ per year at 0.15 €/kWh
43 %share of energy used for aeration

what this estimate is · Inputs: 15,851 p.e. of reported load; equivalent average load 10,937 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

1.2estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (3,170 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Villafranca_padovana_via_firenze,_loc_taggi_di_sopra4.0 km12,0009,510primary, secondary and tertiary
Cadoneghe_via_matteotti5.0 km50,00047,362primary, secondary and tertiary
Rubano_via_mazzini5.4 km22,00016,471primary, secondary and tertiary
Mestrino_via_petrarca8.5 km15,00012,185primary, secondary and tertiary
Padova_via_pontedera,_loc_guizza9.9 km13,00012,480primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Limena_Via_A_Volta report?

Reported size: 20,000 h-e design capacity. Received load: 15,851 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Limena_Via_A_Volta?

Aguas SB simulator reference scenario for 15,851 p.e. of reported load: 561,116 kWh per year (51.3 kWh per p.e. of average load), with aeration as 43 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.