Worldwide wastewater treatment observatory · Italy

Aguas SB Observatory · public data to understand water

WWTP Palazzo_S_G_Cda_Piani

Italy · official identifier IT17Q150000121

3,000h-e design capacity (2022) · 2502nd of 3,726 (tied with 156 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT17Q150000121 · reported size 3,000 h-e design capacity · received load 5,300 h-e · reported treatment: PS · data year 2022. 2502nd of 3,726 records with reported size in the inventory of Italy (tied with 156 others); < 0.01 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 8.1 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

3,000h-e design capacity
5,300h-e received load (2022)
177 %reported load/capacity ratio (not hydraulic utilisation)
2502nd of 3,726by reported size among the 3,726 records with a size in the inventory (tied with 156 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates40.9353, 15.9976 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

186,134reference kWh per year for this load
50.9kWh per h-e (average load) per year
27,920€ per year at 0.15 €/kWh
67 %share of energy used for aeration

what this estimate is · Inputs: 5,300 p.e. of reported load; equivalent average load 3,657 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.4estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (1,060 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Spinazzola_nuovo8.1 km10,0766,854primary, secondary and tertiary
Genzano_di_lucania_cda_gaudemanno9.3 km5,0004,879primary and secondary
Genzano_di_lucania_visciola_zona_pip10.2 km500331primary and secondary
Venosa_fiumara_di_venosa13.8 km23,00013,000primary and secondary
Forenza_cda_olecina14.2 km3,8002,500primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Palazzo_S_G_Cda_Piani report?

Reported size: 3,000 h-e design capacity. Received load: 5,300 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Palazzo_S_G_Cda_Piani?

Aguas SB simulator reference scenario for 5,300 p.e. of reported load: 186,134 kWh per year (50.9 kWh per p.e. of average load), with aeration as 67 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.