WWTP PORDENONE_VIA_BURIDA

Italy · official identifier IT06000000000079

50,000h-e design capacity (2022) · 381st of 3,726 (tied with 26 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT06000000000079 · reported size 50,000 h-e design capacity · received load 37,641 h-e · reported treatment: PST · data year 2022. 381st of 3,726 records with reported size in the inventory of Italy (tied with 26 others); 0.05 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 2.4 km · 11 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

50,000h-e design capacity
37,641h-e received load (2022)
75 %reported load/capacity ratio (not hydraulic utilisation)
381st of 3,726by reported size among the 3,726 records with a size in the inventory (tied with 26 others) · 0.05 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionyes
Statusactive
Reported coordinates45.9492, 12.6448 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,292,279reference kWh per year for this load
49.8kWh per h-e (average load) per year
193,842€ per year at 0.15 €/kWh
49 %share of energy used for aeration

what this estimate is · Inputs: 37,641 p.e. of reported load; equivalent average load 25,972 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

2.7estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (7,528 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Porcia_via_del_platano2.4 km15,00012,441primary, secondary and tertiary
Pordenone_via_savio_vallenoncello2.9 km15,0002,841primary, secondary and tertiary
Cordenons_via_aquileia3.9 km8,0003,950primary, secondary and tertiary
Cordenons_via_chiavornicco4.7 km15,0008,000primary, secondary and tertiary
Fiume_veneto_via_tavella6.3 km8,7006,147primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP PORDENONE_VIA_BURIDA report?

Reported size: 50,000 h-e design capacity. Received load: 37,641 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of PORDENONE_VIA_BURIDA?

Aguas SB simulator reference scenario for 37,641 p.e. of reported load: 1,292,279 kWh per year (49.8 kWh per p.e. of average load), with aeration as 49 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.