Worldwide wastewater treatment observatory · Italy
Aguas SB Observatory · public data to understand water
WWTP RSFG0170470701_Cedegolo_Grevo_Dosina
Italy · official identifier IT03Q13000000204
not reportedh-e design capacity (2022)
European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT03Q13000000204 · reported size not reported h-e design capacity · received load 112 h-e · data year 2022. Reported data with their source; estimates are not measurements of the plant.
Aguas SB does not manage this wastewater treatment plant.
WHAT THE DATA REPORT
Reported data official data · 2022
| Treatment | not reported |
|---|---|
| Nitrogen removal | not reported |
| Phosphorus removal | not reported |
| UV disinfection | not reported |
| Status | active |
| Reported coordinates | 46.0727, 10.3504 approximate position · location awaiting cross-checking |
| Source and year | European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record |
Another record in the same inventory lies within 50 m: RSFG0170470501_Cedegolo_Grevo_Capoluogo · IT03Q13000000202, RSFG0170470601_Cedegolo_Capoluogo · IT03Q13000000203, RSFG0170470801_Cedegolo_Grevo_Gazzoli · IT03Q13000000205, RSFG0171760201_Sellero_S8_M · IT03Q11000000193, RSFG0171760501_Sellero_Novelle · IT03Q13000000206, RSFG0171760701_Sellero_Novelle_2 · IT03Q13000000207, RSFG0171760801_Sellero_Novelle_Valle_Dosbo · IT03Q13000000208. The source does not state whether it is the same facility.
REGULATORY REFERENCES
Referencia normativa: Italy
Regulatory framework of Italy. Individual applicability is not determined in this profile.
SCENARIO
Reference energy scenario for this load estimate · simulator engine
what this estimate is · Inputs: 112 p.e. of reported load; equivalent average load 76 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.
Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.
WATER THAT COULD RETURN
Reuse potential
what this estimate is · Volume estimated from the reported load (22 m³/day of reference), not measured or available for reclamation.
NEARBY PLANTS
Nearby wastewater treatment plants
Nearby plants are not shown: this plant's location awaits cross-checking.
QUESTIONS
Frequently asked questions about this plant
What capacity does WWTP RSFG0170470701_Cedegolo_Grevo_Dosina report?
Reported size: not reported h-e design capacity. Received load: 112 h-e. Units are retained without conversion.
What treatment is reported?
Treatment not reported. Nitrogen, phosphorus and UV are shown only when explicitly reported.
How much energy would a reference plant use with the load of RSFG0170470701_Cedegolo_Grevo_Dosina?
Aguas SB simulator reference scenario for 112 p.e. of reported load: 10,117 kWh per year (133.3 kWh per p.e. of average load), with aeration as 33 % of consumption. Estimate with the country reference profile; not a measurement of the plant.
SOURCE AND CORRECTIONS
Source
reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.