Worldwide wastewater treatment observatory · Italy

Aguas SB Observatory · public data to understand water

WWTP SANTA_MARINA_IMPIANTO_FRAZ_POLICASTRO

Italy · official identifier IT15Q90000003648

10,000h-e design capacity (2022) · 1255th of 3,726 (tied with 108 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT15Q90000003648 · reported size 10,000 h-e design capacity · received load 4,778 h-e · reported treatment: PS · data year 2022. 1255th of 3,726 records with reported size in the inventory of Italy (tied with 108 others); < 0.01 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 3.9 km · 13 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

10,000h-e design capacity
4,778h-e received load (2022)
48 %reported load/capacity ratio (not hydraulic utilisation)
1255th of 3,726by reported size among the 3,726 records with a size in the inventory (tied with 108 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates40.0719, 15.5206 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

168,976reference kWh per year for this load
51.2kWh per h-e (average load) per year
25,346€ per year at 0.15 €/kWh
67 %share of energy used for aeration

what this estimate is · Inputs: 4,778 p.e. of reported load; equivalent average load 3,298 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.3estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (956 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Santa_marina_impianto_del_centro3.9 km2,0001,344primary and secondary
Ispani_impianto_di_depurazione_in_loc_capitello4.0 km8,0005,550primary and secondary
San_giovanni_a_piro_depuratore_in_loc_bosco5.3 km1,0001,000primary and secondary
Vibonati_impianto_irace5.8 km10,00011,227primary and secondary
San_giovanni_a_piro_depuratore_comunale_in_s_giovanni_a_piro6.0 km2,0002,000primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP SANTA_MARINA_IMPIANTO_FRAZ_POLICASTRO report?

Reported size: 10,000 h-e design capacity. Received load: 4,778 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of SANTA_MARINA_IMPIANTO_FRAZ_POLICASTRO?

Aguas SB simulator reference scenario for 4,778 p.e. of reported load: 168,976 kWh per year (51.2 kWh per p.e. of average load), with aeration as 67 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.