Worldwide wastewater treatment observatory · Italy

Aguas SB Observatory · public data to understand water

WWTP VERGATO

Italy · official identifier IT08000000000042

9,000h-e design capacity (2022) · 1415th of 3,726 (tied with 49 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT08000000000042 · reported size 9,000 h-e design capacity · received load 6,349 h-e · reported treatment: PST · data year 2022. 1415th of 3,726 records with reported size in the inventory of Italy (tied with 49 others); < 0.01 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 7.3 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

9,000h-e design capacity
6,349h-e received load (2022)
71 %reported load/capacity ratio (not hydraulic utilisation)
1415th of 3,726by reported size among the 3,726 records with a size in the inventory (tied with 49 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates44.2888, 11.1131 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Italy

Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

220,462reference kWh per year for this load
50.3kWh per h-e (average load) per year
33,069€ per year at 0.15 €/kWh
68 %share of energy used for aeration

what this estimate is · Inputs: 6,349 p.e. of reported load; equivalent average load 4,382 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.5estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (1,270 m³/day of reference), not measured or available for reclamation.

LOCATION

Italy: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Monzuno_rioveggio7.3 km3,0002,210primary, secondary and tertiary
Vergato_riola7.3 km3,0002,212primary, secondary and tertiary
Marzabotto10.4 km5,0003,041primary, secondary and tertiary
Zocca_bondiglio12.1 km3,7003,168primary, secondary and tertiary
Montese13.9 km3,8003,163primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP VERGATO report?

Reported size: 9,000 h-e design capacity. Received load: 6,349 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of VERGATO?

Aguas SB simulator reference scenario for 6,349 p.e. of reported load: 220,462 kWh per year (50.3 kWh per p.e. of average load), with aeration as 68 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.