Worldwide wastewater treatment observatory · Netherlands
Aguas SB Observatory · public data to understand water
WWTP UWWTP 'S HERTOGENBOSCH
Netherlands · official identifier NL27008
248,200h-e design capacity (2022) · 14th of 315
European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier NL27008 · reported size 248,200 h-e design capacity · received load 218,866 h-e · reported treatment: PST · data year 2022. 14th of 315 records with reported size in the inventory of Netherlands; 1.2 % of the sum of those 315 records in h-e (sum of records, not national capacity); nearest inventoried plant at 10.5 km. Reported data with their source; estimates are not measurements of the plant.
Aguas SB does not manage this wastewater treatment plant.
WHAT THE DATA REPORT
Reported data official data · 2022
| Treatment | primary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels |
|---|---|
| Nitrogen removal | yes |
| Phosphorus removal | yes |
| UV disinfection | not reported |
| Status | active |
| Reported coordinates | 51.7210, 5.2834 precision reported by the source: level 1 what it means |
| Source and year | European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record |
FUENTES PÚBLICAS
What public sources report
Documented milestones
- 2025-09-25 · In September 2025, a permit extended the temporary use of a cover to limit odour at the sludge unloading building of the Den Bosch wastewater treatment plant. Province of North Brabant
Other published data
| Mean annual volume treated reported in the 2022 cycle | 19,147,599 m³/year (2022) · source |
|---|
Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L03; it does not change the official data.
REGULATORY REFERENCES
Referencia normativa: Netherlands
Regulatory framework of Netherlands · Directive (EU) 2024/3019: reported-capacity band 150,000 p.e. or more; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.
SCENARIO
Reference energy scenario for this load estimate · simulator engine
what this estimate is · Inputs: 218,866 p.e. of reported load; equivalent average load 218,605 p.e. with the reference profile of Netherlands (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.
Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.
WATER THAT COULD RETURN
Reuse potential
what this estimate is · Volume estimated from the reported load (57,781 m³/day of reference), not measured or available for reclamation.
NEARBY PLANTS
Nearby wastewater treatment plants
| Plant | Distance | Capacity (h-e) | Load 2022 | Treatment |
|---|---|---|---|---|
| Uwwtp Zaltbommel | 10.5 km | 49,500 | 64,900 | primary, secondary and tertiary |
| Uwwtp Vinkel | 11.5 km | 42,165 | 53,716 | primary, secondary and tertiary |
| Uwwtp Haaften | 12.1 km | 11,250 | 13,666 | primary, secondary and tertiary |
| Uwwtp Boxtel | 12.9 km | 62,280 | 44,933 | primary, secondary and tertiary |
| Uwwtp Waalwijk | 14.6 km | 51,300 | 49,100 | primary, secondary and tertiary |
Distances are between reported coordinates; proximity does not establish a hydraulic connection.
QUESTIONS
Frequently asked questions about this plant
What capacity does WWTP UWWTP 'S HERTOGENBOSCH report?
Reported size: 248,200 h-e design capacity. Received load: 218,866 h-e. Units are retained without conversion.
What treatment is reported?
Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.
How much energy would a reference plant use with the load of UWWTP 'S HERTOGENBOSCH?
Aguas SB simulator reference scenario for 218,866 p.e. of reported load: 7,275,237 kWh per year (33.3 kWh per p.e. of average load), with aeration as 56 % of consumption. Estimate with the country reference profile; not a measurement of the plant.
SOURCE AND CORRECTIONS
Source
reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.