Worldwide wastewater treatment observatory · Poland
Aguas SB Observatory · public data to understand water
WWTP Bieławin
Poland · official identifier PLLE0030
124,800h-e design capacity (2022) · 84th of 1,654
European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier PLLE0030 · reported size 124,800 h-e design capacity · received load 100,332 h-e · reported treatment: PST · data year 2022. 84th of 1,654 records with reported size in the inventory of Poland; 0.23 % of the sum of those 1,654 records in h-e (sum of records, not national capacity); nearest inventoried plant at 15.8 km. Reported data with their source; estimates are not measurements of the plant.
Aguas SB does not manage this wastewater treatment plant.
WHAT THE DATA REPORT
Reported data official data · 2022
| Treatment | primary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels |
|---|---|
| Nitrogen removal | yes |
| Phosphorus removal | yes |
| UV disinfection | not reported |
| Status | active |
| Reported coordinates | 51.1503, 23.4755 precision reported by the source: level 2 what it means |
| Source and year | European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record |
FUENTES PÚBLICAS
What public sources report
Population of the served area (Chełm): 62,488 inhabitants (2024, Polish National Water Management Authority).
Documented milestones
- 2015-02-01 · The plant permit (RS-V.7322.25.2014.AGL) became final, according to the national report. Polish National Water Management Authority
Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L07; it does not change the official data.
REGULATORY REFERENCES
Referencia normativa: Poland
Regulatory framework of Poland · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.
SCENARIO
Reference energy scenario for this load estimate · simulator engine
what this estimate is · Inputs: 100,332 p.e. of reported load; equivalent average load 78,200 p.e. with the reference profile of Poland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.
Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.
WATER THAT COULD RETURN
Reuse potential
what this estimate is · Volume estimated from the reported load (10,836 m³/day of reference), not measured or available for reclamation.
NEARBY PLANTS
Nearby wastewater treatment plants
| Plant | Distance | Capacity (h-e) | Load 2022 | Treatment |
|---|---|---|---|---|
| Rejowiec | 15.8 km | 4,373 | 2,475 | primary and secondary |
| Miejski Zakład Wodociągów i Kanalizacji | 16.6 km | 4,400 | 3,909 | primary and secondary |
| Wierzbica | 17.1 km | 2,250 | 2,098 | primary and secondary |
| Bytyń | 23.5 km | 3,323 | 2,546 | primary and secondary |
| Miejska Oczyszczalnia Ścieków Komunalnych · Plle0160 | 26.7 km | 34,300 | 21,134 | primary, secondary and tertiary |
Distances are between reported coordinates; proximity does not establish a hydraulic connection.
QUESTIONS
Frequently asked questions about this plant
What capacity does WWTP Bieławin report?
Reported size: 124,800 h-e design capacity. Received load: 100,332 h-e. Units are retained without conversion.
What treatment is reported?
Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.
How much energy would a reference plant use with the load of Bieławin?
Aguas SB simulator reference scenario for 100,332 p.e. of reported load: 2,553,262 kWh per year (32.7 kWh per p.e. of average load), with aeration as 61 % of consumption. Estimate with the country reference profile; not a measurement of the plant.
SOURCE AND CORRECTIONS
Source
reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.