Worldwide wastewater treatment observatory · Poland

Aguas SB Observatory · public data to understand water

WWTP Ińsko

Poland · official identifier PLZA0820

8,624h-e design capacity (2022) · 793rd of 1,654 (tied with 1 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier PLZA0820 · reported size 8,624 h-e design capacity · received load 2,157 h-e · reported treatment: PS · data year 2022. 793rd of 1,654 records with reported size in the inventory of Poland (tied with 1 others); 0.02 % of the sum of those 1,654 records in h-e (sum of records, not national capacity); nearest inventoried plant at 12.5 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

8,624h-e design capacity
2,157h-e received load (2022)
25 %reported load/capacity ratio (not hydraulic utilisation)
793rd of 1,654by reported size among the 1,654 records with a size in the inventory (tied with 1 others) · 0.02 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates53.4321, 15.5492 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Poland

Regulatory framework of Poland · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

79,345reference kWh per year for this load
47.2kWh per h-e (average load) per year
11,902€ per year at 0.15 €/kWh
71 %share of energy used for aeration

what this estimate is · Inputs: 2,157 p.e. of reported load; equivalent average load 1,681 p.e. with the reference profile of Poland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (233 m³/day of reference), not measured or available for reclamation.

LOCATION

Poland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Węgorzyno12.5 km3,9003,380primary and secondary
Oczyszczalnia Dobrzany12.7 km8,3505,008primary and secondary
Łobez14.1 km19,80010,023primary, secondary and tertiary
Komunalna Oczyszczalnia Ścieków W Chociwlu15.0 km8,1003,196primary and secondary
Drawsko Pomorskie18.5 km14,67314,320primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Ińsko report?

Reported size: 8,624 h-e design capacity. Received load: 2,157 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Ińsko?

Aguas SB simulator reference scenario for 2,157 p.e. of reported load: 79,345 kWh per year (47.2 kWh per p.e. of average load), with aeration as 71 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.