Worldwide wastewater treatment observatory · Poland

Aguas SB Observatory · public data to understand water

WWTP Murów

Poland · official identifier PLOP0320

6,000h-e design capacity (2022) · 1023rd of 1,654 (tied with 21 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier PLOP0320 · reported size 6,000 h-e design capacity · received load 2,105 h-e · reported treatment: PS · data year 2022. 1023rd of 1,654 records with reported size in the inventory of Poland (tied with 21 others); 0.01 % of the sum of those 1,654 records in h-e (sum of records, not national capacity); nearest inventoried plant at 12.4 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

6,000h-e design capacity
2,105h-e received load (2022)
35 %reported load/capacity ratio (not hydraulic utilisation)
1023rd of 1,654by reported size among the 1,654 records with a size in the inventory (tied with 21 others) · 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates50.8600, 17.9933 precision reported by the source: level 0 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Poland

Regulatory framework of Poland · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

77,435reference kWh per year for this load
47.3kWh per h-e (average load) per year
11,615€ per year at 0.15 €/kWh
71 %share of energy used for aeration

what this estimate is · Inputs: 2,105 p.e. of reported load; equivalent average load 1,638 p.e. with the reference profile of Poland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (227 m³/day of reference), not measured or available for reclamation.

LOCATION

Poland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Oczyszczalnia Ścieków W Pokoju12.4 km2,1501,967primary and secondary
Trzebiszyn14.0 km3,6672,643primary and secondary
Oczyszczalnia Ścieków W Kotorzu Małym14.0 km25,80018,300primary, secondary and tertiary
Stare Siołkowice17.4 km4,7206,420primary and secondary
Wołczyn17.9 km10,3008,285primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Murów report?

Reported size: 6,000 h-e design capacity. Received load: 2,105 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Murów?

Aguas SB simulator reference scenario for 2,105 p.e. of reported load: 77,435 kWh per year (47.3 kWh per p.e. of average load), with aeration as 71 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.