Worldwide wastewater treatment observatory · Poland

Aguas SB Observatory · public data to understand water

WWTP Oczyszczalnia Ścieków w Złochowicach PSO MASKPOL S.A. Koniec

Poland · official identifier PLSL1520N

8,000h-e design capacity (2022) · 838th of 1,654 (tied with 13 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier PLSL1520N · reported size 8,000 h-e design capacity · received load 1,231 h-e · reported treatment: PS · data year 2022. 838th of 1,654 records with reported size in the inventory of Poland (tied with 13 others); 0.01 % of the sum of those 1,654 records in h-e (sum of records, not national capacity); nearest inventoried plant at 4.5 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

8,000h-e design capacity
1,231h-e received load (2022)
15 %reported load/capacity ratio (not hydraulic utilisation)
838th of 1,654by reported size among the 1,654 records with a size in the inventory (tied with 13 others) · 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates50.5457, 18.4753 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Regulatory reference: Poland

Regulatory framework of Poland · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

47,230reference kWh per year for this load
49.2kWh per h-e (average load) per year
7,084€ per year at 0.15 €/kWh
68 %share of energy used for aeration

what this estimate is · Inputs: 1,231 p.e. of reported load; equivalent average load 960 p.e. with the reference profile of Poland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (133 m³/day of reference), not measured or available for reclamation.

LOCATION

Poland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Coma-Tec 20/250-2/P4.5 km4,0002,489primary and secondary
Zawadzkie7.0 km10,5009,180primary and secondary
Oczyszczalnia Ścieków Dla Miasta Toszek i Przyległych Sołect10.5 km7,2603,605primary and secondary
Oczyszczalnia Ścieków W Strzelcach Opolskich10.7 km40,38038,073primary, secondary and tertiary
Krupski Młyn11.1 km3,0832,268primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Oczyszczalnia Ścieków w Złochowicach PSO MASKPOL S.A. Koniec report?

Reported size: 8,000 h-e design capacity. Received load: 1,231 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Oczyszczalnia Ścieków w Złochowicach PSO MASKPOL S.A. Koniec?

Aguas SB simulator reference scenario for 1,231 p.e. of reported load: 47,230 kWh per year (49.2 kWh per p.e. of average load), with aeration as 68 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.