Worldwide wastewater treatment observatory · Romania

Aguas SB Observatory · public data to understand water

WWTP ROWP ASOC INTERCOMUNITARA DE DEZVOLTARE STREMT-RAMET - EV VA

Romania · official identifier ROWP_7776_01

1,866h-e design capacity (2022) · 1253rd of 1,622 (tied with 1 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier ROWP_7776_01 · reported size 1,866 h-e design capacity · received load 1,006 h-e · reported treatment: PS · data year 2022. 1253rd of 1,622 records with reported size in the inventory of Romania (tied with 1 others); < 0.01 % of the sum of those 1,622 records in h-e (sum of records, not national capacity); nearest inventoried plant at 13.1 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

1,866h-e design capacity
1,006h-e received load (2022)
54 %reported load/capacity ratio (not hydraulic utilisation)
1253rd of 1,622by reported size among the 1,622 records with a size in the inventory (tied with 1 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates46.3009, 23.5244 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Romania

Regulatory framework of Romania · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

33,356reference kWh per year for this load
73.6kWh per h-e (average load) per year
5,003€ per year at 0.15 €/kWh
48 %share of energy used for aeration

what this estimate is · Inputs: 1,006 p.e. of reported load; equivalent average load 453 p.e. with the reference profile of Romania (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (161 m³/day of reference), not measured or available for reclamation.

LOCATION

Romania: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Stremt13.7 km1,866541primary and secondary
Rowp Galda de Jos + Mesentea15.4 km3,5001,160primary and secondary
Sucursala Aiud -Radesti15.6 km780219primary and secondary
Sucursala Aiud16.9 km24,00016,647primary, secondary and tertiary
Sucursala Alba Iulia- Teius19.0 km10,000323primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP ROWP ASOC INTERCOMUNITARA DE DEZVOLTARE STREMT-RAMET - EV VA report?

Reported size: 1,866 h-e design capacity. Received load: 1,006 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of ROWP ASOC INTERCOMUNITARA DE DEZVOLTARE STREMT-RAMET - EV VA?

Aguas SB simulator reference scenario for 1,006 p.e. of reported load: 33,356 kWh per year (73.6 kWh per p.e. of average load), with aeration as 48 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.