Romania · official identifier ROWP_63456_01
8,500h-e design capacity (2022) · 263rd of 1,622 (tied with 3 others)
European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier ROWP_63456_01 · reported size 8,500 h-e design capacity · received load 5,362 h-e · reported treatment: PS · data year 2022. 263rd of 1,622 records with reported size in the inventory of Romania (tied with 3 others); 0.04 % of the sum of those 1,622 records in h-e (sum of records, not national capacity); nearest inventoried plant at 12.2 km. Reported data with their source; estimates are not measurements of the plant.
Aguas SB does not manage this wastewater treatment plant.
WHAT THE DATA REPORT
Reported data official data · 2022
| Treatment | primary + secondary (as reported to the EEA: PS) · reported levels |
|---|---|
| Nitrogen removal | not reported |
| Phosphorus removal | not reported |
| UV disinfection | not reported |
| Status | active |
| Reported coordinates | 46.0790, 25.5680 precision reported by the source: level 1 what it means |
| Source and year | European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record |
REGULATORY REFERENCES
Referencia normativa: Romania
Regulatory framework of Romania · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.
SCENARIO
Reference energy scenario for this load estimate · simulator engine
what this estimate is · Inputs: 5,362 p.e. of reported load; equivalent average load 2,417 p.e. with the reference profile of Romania (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.
Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.
WATER THAT COULD RETURN
Reuse potential
what this estimate is · Volume estimated from the reported load (858 m³/day of reference), not measured or available for reclamation.
NEARBY PLANTS
Nearby wastewater treatment plants
| Plant | Distance | Capacity (h-e) | Load 2022 | Treatment |
|---|---|---|---|---|
| Rowp Primaria Bradut | 12.2 km | 5,000 | 956 | primary and secondary |
| Brasov- St.Zonala Hoghiz | 22.9 km | 16,500 | 4,913 | primary, secondary and tertiary |
| Rowp Gospodarie Comunala Baile Tusnad | 23.8 km | 4,000 | 1,290 | primary and secondary |
| Sector Bodoc | 24.2 km | 1,800 | 696 | primary and secondary |
| Brasov -St Zonala Feldioara | 29.8 km | 142,000 | 14,875 | primary, secondary and tertiary |
Distances are between reported coordinates; proximity does not establish a hydraulic connection.
QUESTIONS
Frequently asked questions about this plant
What capacity does WWTP ROWP PRIMARIA BARAOLT- SERVICIUL PUBLIC DE ALIMENTARE SI CAN report?
Reported size: 8,500 h-e design capacity. Received load: 5,362 h-e. Units are retained without conversion.
What treatment is reported?
Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.
How much energy would a reference plant use with the load of ROWP PRIMARIA BARAOLT- SERVICIUL PUBLIC DE ALIMENTARE SI CAN?
Aguas SB simulator reference scenario for 5,362 p.e. of reported load: 135,078 kWh per year (55.9 kWh per p.e. of average load), with aeration as 63 % of consumption. Estimate with the country reference profile; not a measurement of the plant.