Worldwide wastewater treatment observatory · Slovenia

Aguas SB Observatory · public data to understand water

WWTP UWWTP_ŠOŠTANJ (ŠALEŠKE DOLINE)

Slovenia · official identifier SI_KCN_00081

50,000h-e design capacity (2022) · 12th of 118

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier SI_KCN_00081 · reported size 50,000 h-e design capacity · received load 40,851 h-e · reported treatment: PST · data year 2022. 12th of 118 records with reported size in the inventory of Slovenia; 2.1 % of the sum of those 118 records in h-e (sum of records, not national capacity); nearest inventoried plant at 4.7 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

50,000h-e design capacity
40,851h-e received load (2022)
82 %reported load/capacity ratio (not hydraulic utilisation)
12th of 118by reported size among the 118 records with a size in the inventory · 2.1 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates46.3798, 15.0366 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Slovenia

Regulatory framework of Slovenia · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,694,097reference kWh per year for this load
41.4kWh per h-e (average load) per year
254,115€ per year at 0.15 €/kWh
55 %share of energy used for aeration

what this estimate is · Inputs: 40,851 p.e. of reported load; equivalent average load 40,893 p.e. with the reference profile of Slovenia (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

3.1estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (8,579 m³/day of reference), not measured or available for reclamation.

LOCATION

Slovenia: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Uwwtp_mozirje6.3 km6,0005,630primary and secondary
Uwwtp_mislinja12.2 km2,7002,241primary and secondary
Uwwtp_slovenj Gradec17.5 km20,30012,534primary, secondary and tertiary
Uwwtp_črna Na Koroškem17.7 km3,2002,360primary and secondary
Uwwtp_žalec (Kasaze)19.6 km60,00030,199primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP UWWTP_ŠOŠTANJ (ŠALEŠKE DOLINE) report?

Reported size: 50,000 h-e design capacity. Received load: 40,851 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of UWWTP_ŠOŠTANJ (ŠALEŠKE DOLINE)?

Aguas SB simulator reference scenario for 40,851 p.e. of reported load: 1,694,097 kWh per year (41.4 kWh per p.e. of average load), with aeration as 55 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.