Worldwide wastewater treatment observatory · Sweden

Aguas SB Observatory · public data to understand water

WWTP Bogryd avloppsreningsverk

Sweden · official identifier SE1490-1027

9,500h-e design capacity (2022) · 206th of 434 (tied with 5 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier SE1490-1027 · reported size 9,500 h-e design capacity · received load 1,926 h-e · reported treatment: PS · data year 2022. 206th of 434 records with reported size in the inventory of Sweden (tied with 5 others); 0.07 % of the sum of those 434 records in h-e (sum of records, not national capacity); nearest inventoried plant at 9.3 km · 1 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

9,500h-e design capacity
1,926h-e received load (2022)
20 %reported load/capacity ratio (not hydraulic utilisation)
206th of 434by reported size among the 434 records with a size in the inventory (tied with 5 others) · 0.07 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates57.6032, 12.7872 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Sweden

Regulatory framework of Sweden · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

98,031reference kWh per year for this load
51.0kWh per h-e (average load) per year
14,705€ per year at 0.15 €/kWh
66 %share of energy used for aeration

what this estimate is · Inputs: 1,926 p.e. of reported load; equivalent average load 1,923 p.e. with the reference profile of Sweden (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.2estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (456 m³/day of reference), not measured or available for reclamation.

LOCATION

Sweden: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Sobackens Avfallsupplag9.3 km150,00088,343primary and secondary
Bollebygds Avloppsreningsverk16.3 km6,0004,700primary and secondary
Skene Avloppsreningsverk16.6 km50,00020,800primary and secondary
Ravlanda Avr-Verk17.8 km3,0002,800primary and secondary
Svenljunga Avloppsreningsverk23.5 km7,0005,996primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Bogryd avloppsreningsverk report?

Reported size: 9,500 h-e design capacity. Received load: 1,926 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Bogryd avloppsreningsverk?

Aguas SB simulator reference scenario for 1,926 p.e. of reported load: 98,031 kWh per year (51.0 kWh per p.e. of average load), with aeration as 66 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.