Worldwide wastewater treatment observatory · Switzerland

Aguas SB Observatory · public data to understand water

WWTP LAUSANNE

Switzerland · official identifier CH_WWTP_558600

412,500h-e design capacity (2022) · 6th of 705

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier CH_WWTP_558600 · reported size 412,500 h-e design capacity · received load 186,912 h-e · reported treatment: PST · data year 2022. 6th of 705 records with reported size in the inventory of Switzerland; 2.5 % of the sum of those 705 records in h-e (sum of records, not national capacity); nearest inventoried plant at 6.1 km · 13 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

412,500h-e design capacity
186,912h-e received load (2022)
45 %reported load/capacity ratio (not hydraulic utilisation)
6th of 705by reported size among the 705 records with a size in the inventory · 2.5 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalnot reported
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates46.5207, 6.5908 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

FUENTES PÚBLICAS

What public sources report

Documented milestones

  • 1964 · The Vidy wastewater treatment plant in Lausanne entered service. City of Lausanne

Other published data

Mean annual volume treated reported in the 2022 cycle32,849,235 m³/year (2022) · source

Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L02; it does not change the official data.

REGULATORY REFERENCES

Referencia normativa: Switzerland

Regulatory framework of Switzerland. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

7,077,096reference kWh per year for this load
33.5kWh per h-e (average load) per year
1,061,564€ per year at 0.15 €/kWh
53 %share of energy used for aeration

what this estimate is · Inputs: 186,912 p.e. of reported load; equivalent average load 211,013 p.e. with the reference profile of Switzerland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

23estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (62,989 m³/day of reference), not measured or available for reclamation.

LOCATION

Switzerland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Morges6.1 km56,25039,850primary, secondary and tertiary
Pully6.2 km40,00014,757primary, secondary and tertiary
Bremblens6.5 km10,0008,186primary, secondary and tertiary
Morrens-Mebre7.1 km687570primary, secondary and tertiary
Cugy7.5 km2,5001,535primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP LAUSANNE report?

Reported size: 412,500 h-e design capacity. Received load: 186,912 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of LAUSANNE?

Aguas SB simulator reference scenario for 186,912 p.e. of reported load: 7,077,096 kWh per year (33.5 kWh per p.e. of average load), with aeration as 53 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.