Worldwide wastewater treatment observatory · Switzerland

Aguas SB Observatory · public data to understand water

WWTP Prato Leventina

Switzerland · official identifier CH_WWTP_507801

500h-e design capacity (2022) · 618th of 705 (tied with 9 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier CH_WWTP_507801 · reported size 500 h-e design capacity · received load 129 h-e · reported treatment: PS · data year 2022. 618th of 705 records with reported size in the inventory of Switzerland (tied with 9 others); < 0.01 % of the sum of those 705 records in h-e (sum of records, not national capacity); nearest inventoried plant at 1.0 km · 3 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

500h-e design capacity
129h-e received load (2022)
26 %reported load/capacity ratio (not hydraulic utilisation)
618th of 705by reported size among the 705 records with a size in the inventory (tied with 9 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates46.4834, 8.7525 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Switzerland

Regulatory framework of Switzerland. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

15,662reference kWh per year for this load
108.7kWh per h-e (average load) per year
2,349€ per year at 0.15 €/kWh
39 %share of energy used for aeration

what this estimate is · Inputs: 129 p.e. of reported load; equivalent average load 144 p.e. with the reference profile of Switzerland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (43 m³/day of reference), not measured or available for reclamation.

LOCATION

Switzerland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Rodi (Prato Leventina)1.0 km710201primary and secondary
Varenzo (Quinto)3.4 km3,620777primary, secondary and tertiary
Carì (Faido)5.5 km1,88029primary and secondary
Airolo11.0 km5,4401,301primary, secondary and tertiary
Olivone (Blenio)15.1 km1,880836primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Prato Leventina report?

Reported size: 500 h-e design capacity. Received load: 129 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Prato Leventina?

Aguas SB simulator reference scenario for 129 p.e. of reported load: 15,662 kWh per year (108.7 kWh per p.e. of average load), with aeration as 39 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.