Worldwide wastewater treatment observatory · Switzerland

Aguas SB Observatory · public data to understand water

WWTP Scuol (S-charl)

Switzerland · official identifier CH_WWTP_376202

375h-e design capacity (2022) · 653rd of 705 (tied with 12 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier CH_WWTP_376202 · reported size 375 h-e design capacity · received load 8 h-e · reported treatment: PST · data year 2022. 653rd of 705 records with reported size in the inventory of Switzerland (tied with 12 others); < 0.01 % of the sum of those 705 records in h-e (sum of records, not national capacity); nearest inventoried plant at 9.2 km · 1 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

375h-e design capacity
8h-e received load (2022)
2 %reported load/capacity ratio (not hydraulic utilisation)
653rd of 705by reported size among the 705 records with a size in the inventory (tied with 12 others) · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalnot reported
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates46.7162, 10.3290 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Switzerland

Regulatory framework of Switzerland. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

1,324reference kWh per year for this load
131.7kWh per h-e (average load) per year
199€ per year at 0.15 €/kWh
32 %share of energy used for aeration

what this estimate is · Inputs: 8 p.e. of reported load; equivalent average load 10 p.e. with the reference profile of Switzerland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (3 m³/day of reference), not measured or available for reclamation.

LOCATION

Switzerland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Scuol (Sot Ruinas)9.2 km17,5004,440primary, secondary and tertiary
Scuol (Ftan)10.4 km4,1331,307primary, secondary and tertiary
Scuol (Sur En)11.8 km41337primary and secondary
Scuol (Ardez)11.9 km1,2501,002primary and secondary
Valsot (Ramosch)13.1 km1,0621,008primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Scuol (S-charl) report?

Reported size: 375 h-e design capacity. Received load: 8 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Scuol (S-charl)?

Aguas SB simulator reference scenario for 8 p.e. of reported load: 1,324 kWh per year (131.7 kWh per p.e. of average load), with aeration as 32 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.