Worldwide wastewater treatment observatory · Switzerland

Aguas SB Observatory · public data to understand water

WWTP STADEL

Switzerland · official identifier CH_WWTP_010001

2,200h-e design capacity (2022) · 453rd of 705 (tied with 1 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier CH_WWTP_010001 · reported size 2,200 h-e design capacity · received load 1,749 h-e · reported treatment: PST · data year 2022. 453rd of 705 records with reported size in the inventory of Switzerland (tied with 1 others); 0.01 % of the sum of those 705 records in h-e (sum of records, not national capacity); nearest inventoried plant at 4.5 km · 6 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

2,200h-e design capacity
1,749h-e received load (2022)
80 %reported load/capacity ratio (not hydraulic utilisation)
453rd of 705by reported size among the 705 records with a size in the inventory (tied with 1 others) · 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalnot reported
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates47.5460, 8.4754 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Switzerland

Regulatory framework of Switzerland. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

102,749reference kWh per year for this load
52.1kWh per h-e (average load) per year
15,412€ per year at 0.15 €/kWh
63 %share of energy used for aeration

what this estimate is · Inputs: 1,749 p.e. of reported load; equivalent average load 1,973 p.e. with the reference profile of Switzerland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.2estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (589 m³/day of reference), not measured or available for reclamation.

LOCATION

Switzerland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Eglisau4.5 km11,7008,706primary, secondary and tertiary
Buelach5.0 km44,50040,287primary, secondary and tertiary
Niederglatt(Fischb.-Gl.)5.3 km37,75040,515primary, secondary and tertiary
Rorbas7.5 km20,00015,098primary, secondary and tertiary
Ruedlingen8.1 km2,4001,913primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP STADEL report?

Reported size: 2,200 h-e design capacity. Received load: 1,749 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of STADEL?

Aguas SB simulator reference scenario for 1,749 p.e. of reported load: 102,749 kWh per year (52.1 kWh per p.e. of average load), with aeration as 63 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.