Worldwide wastewater treatment observatory · Austria
Aguas SB Observatory · public data to understand water
WWTP Rechnitz
Austria · official identifier ATTP_1-00000055
6,000h-e design capacity (2022) · 367th of 634 (tied with 12 others)
European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier ATTP_1-00000055 · reported size 6,000 h-e design capacity · received load 4,123 h-e · reported treatment: PST · data year 2022. 367th of 634 records with reported size in the inventory of Austria (tied with 12 others); 0.02 % of the sum of those 634 records in h-e (sum of records, not national capacity); nearest inventoried plant at 7.5 km · 1 within 10 km. Reported data with their source; estimates are not measurements of the plant.
Aguas SB does not manage this wastewater treatment plant.
WHAT THE DATA REPORT
Reported data official data · 2022
| Treatment | primary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels |
|---|---|
| Nitrogen removal | yes |
| Phosphorus removal | yes |
| UV disinfection | not reported |
| Status | active |
| Reported coordinates | 47.3015, 16.4534 precision reported by the source: level 2 what it means |
| Source and year | European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record |
REGULATORY REFERENCES
Referencia normativa: Austria
Regulatory framework of Austria · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.
SCENARIO
Reference energy scenario for this load estimate · simulator engine
what this estimate is · Inputs: 4,123 p.e. of reported load; equivalent average load 4,098 p.e. with the reference profile of Austria (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.
Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.
WATER THAT COULD RETURN
Reuse potential
what this estimate is · Volume estimated from the reported load (825 m³/day of reference), not measured or available for reclamation.
NEARBY PLANTS
Nearby wastewater treatment plants
| Plant | Distance | Capacity (h-e) | Load 2022 | Treatment |
|---|---|---|---|---|
| Schandorf - Schachendorf | 7.5 km | 2,000 | 1,116 | primary, secondary and tertiary |
| Burg (Tauchental) | 11.2 km | 7,000 | 2,974 | primary, secondary and tertiary |
| Neumarkt (Tauchental) | 11.9 km | 15,000 | 7,257 | primary, secondary and tertiary |
| Kleinzicken (Tauchental) | 14.1 km | 4,000 | 2,615 | primary, secondary and tertiary |
| Siget / Wart (Mittleres Pinka- Und Zickenbachtal) | 14.2 km | 45,000 | 42,793 | primary, secondary and tertiary |
Distances are between reported coordinates; proximity does not establish a hydraulic connection.
QUESTIONS
Frequently asked questions about this plant
What capacity does WWTP Rechnitz report?
Reported size: 6,000 h-e design capacity. Received load: 4,123 h-e. Units are retained without conversion.
What treatment is reported?
Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.
How much energy would a reference plant use with the load of Rechnitz?
Aguas SB simulator reference scenario for 4,123 p.e. of reported load: 186,882 kWh per year (45.6 kWh per p.e. of average load), with aeration as 71 % of consumption. Estimate with the country reference profile; not a measurement of the plant.
SOURCE AND CORRECTIONS
Source
reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.